Filter interviews by
Clear (1)
I applied via Company Website and was interviewed before Oct 2022. There were 3 interview rounds.
75 question of simple aptitude and technical
An induction machine is an AC electric motor in which the electric current in the rotor needed to produce torque is induced by electromagnetic induction from the magnetic field of the stator winding.
Induction machines are commonly used in various industrial applications for their simplicity, reliability, and low maintenance requirements.
They operate on the principle of electromagnetic induction, where a rotating magnet...
A generator is a device that converts mechanical energy into electrical energy.
Generators are commonly used as backup power sources during power outages.
They can be powered by various sources such as gasoline, diesel, natural gas, or renewable energy sources like solar or wind.
Generators come in different sizes and capacities to meet different power needs.
They consist of an engine, alternator, fuel system, voltage regu...
Voltage rating in multiples of 11 is common due to historical reasons and practical considerations.
Historically, early power systems used 110V and 220V as standard voltages.
Multiples of 11 make it easier to design transformers and other electrical equipment.
Standardizing on multiples of 11 simplifies the distribution and transmission of power.
Common voltage ratings like 110V, 220V, 440V, etc., are all multiples of 11.
Speed control of an AC machine is achieved by varying the frequency of the input power supply.
Speed control is typically done using a variable frequency drive (VFD) which adjusts the frequency of the input power to the motor.
By increasing or decreasing the frequency, the motor speed can be controlled without changing the number of poles in the motor.
For example, in an industrial setting, a VFD may be used to control th...
Lightning impulse test of a power transformer is a high voltage test to simulate lightning strikes and ensure the transformer can withstand sudden voltage surges.
It is a high voltage test conducted to simulate lightning strikes on the transformer
The test is performed to ensure the transformer can withstand sudden voltage surges
It helps in evaluating the insulation strength and overall performance of the transformer
The ...
650kVp is chosen for lighting impulse level for 132kV due to its ability to withstand lightning strikes and protect the equipment.
650kVp is a standard value chosen based on the insulation level required for 132kV systems
Lightning impulse level is selected to ensure equipment can withstand lightning strikes without damage
Higher impulse levels provide better protection against lightning-induced surges
Choosing the right i...
Heat run test of transformer is a test conducted to assess the performance of a transformer under normal operating conditions.
Heat run test involves running the transformer at full load for a specified period of time to evaluate its temperature rise.
The test helps in determining if the transformer can handle the heat generated during normal operation without overheating.
It is essential to ensure that the transformer ca...
Top trending discussions
posted on 30 Jan 2023
I applied via Referral and was interviewed before Jan 2022. There were 2 interview rounds.
posted on 24 Dec 2023
I applied via Campus Placement and was interviewed in Jun 2023. There were 2 interview rounds.
I applied via Recruitment Consultant and was interviewed before Oct 2020. There was 1 interview round.
I have extensive experience in using various piping design tools.
Proficient in using AutoCAD for piping design
Familiar with 3D modeling software like SolidWorks for creating detailed piping layouts
Skilled in using piping design software such as Caesar II for stress analysis
Experience in using PDMS (Plant Design Management System) for piping design and layout
Knowledge of industry standards and codes related to piping de
A protection system is a set of devices and measures designed to prevent damage or harm to equipment, personnel, or the environment in case of a fault or abnormal condition.
Protection systems can include circuit breakers, fuses, relays, and alarms.
They are commonly used in electrical systems to prevent overloads, short circuits, and ground faults.
Protection systems are essential for ensuring the safety and reliability ...
I was interviewed in Feb 2023.
I applied via Recruitment Consulltant and was interviewed before Apr 2022. There were 2 interview rounds.
I was interviewed in Jul 2023.
I applied via Recruitment Consultant and was interviewed in Jun 2020. There were 3 interview rounds.
based on 1 interview
Interview experience
Deputy Manager
52
salaries
| ₹0 L/yr - ₹0 L/yr |
Plant Engineer
42
salaries
| ₹0 L/yr - ₹0 L/yr |
Plant Operator
26
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
13
salaries
| ₹0 L/yr - ₹0 L/yr |
Instrumentation Technician
11
salaries
| ₹0 L/yr - ₹0 L/yr |
National Fertilizers
Rashtriya Chemicals and Fertilizers
Coromandel International
Tata Chemicals