Boiler efficiency can be calculated by measuring the heat input and heat output of the boiler.
Calculate the heat input by measuring the fuel flow rate, fuel calorific value, and fuel consumption.
Calculate the heat output by measuring the steam flow rate and steam enthalpy.
Direct efficiency = (Heat output / Heat input) * 100%
Indirect efficiency = Direct efficiency * Boiler efficiency of other components (like economizer
The monthly maintenance cost of my section is approximately $10,000.
The monthly maintenance cost includes expenses for spare parts, labor, equipment rental, and utilities.
Regular maintenance tasks such as lubrication, inspections, and repairs contribute to the overall cost.
Cost may vary depending on the size of the section, age of equipment, and frequency of maintenance activities.
I applied via Company Website and was interviewed in Mar 2024. There was 1 interview round.
posted on 16 Nov 2023
I applied via Campus Placement and was interviewed in Dec 2023. There was 1 interview round.
An induction motor starts when a rotating magnetic field is created by the stator winding, inducing current in the rotor.
Induction motors start by using the principle of electromagnetic induction.
The stator winding is energized with a three-phase AC current, creating a rotating magnetic field.
This rotating magnetic field induces a current in the rotor, which in turn creates a magnetic field.
The interaction between the ...
posted on 25 Apr 2024
I applied via Referral and was interviewed before Apr 2023. There was 1 interview round.
Synchronisation of generator involves aligning the speed and phase of the generator with the grid before connecting them. Motor protection and maintenance are crucial for ensuring the longevity and efficiency of the motor.
Synchronisation of generator involves matching the frequency, voltage, and phase angle of the generator with the grid before connecting them.
Motor protection includes measures such as overload protect...
I applied via Walk-in and was interviewed before May 2022. There were 3 interview rounds.
Basic technical questions about your field
posted on 11 Sep 2023
I applied via Recruitment Consulltant and was interviewed before Sep 2022. There were 4 interview rounds.
Simple aptitude and reasoning test
posted on 6 Jan 2022
I applied via Naukri.com
Production Engineer
39
salaries
| ₹2.2 L/yr - ₹7.8 L/yr |
Area Sales Incharge
32
salaries
| ₹5 L/yr - ₹8.5 L/yr |
Area Sales Manager
27
salaries
| ₹7.5 L/yr - ₹19.5 L/yr |
Quality Engineer
25
salaries
| ₹1.2 L/yr - ₹7.3 L/yr |
Manager
22
salaries
| ₹10.1 L/yr - ₹23.4 L/yr |
Carborundum Universal Limited
Saint-Gobain
Hindustan Abrasives
Norton Abrasives