Filter interviews by
I applied via Referral and was interviewed before Oct 2020. There were 4 interview rounds.
Power factor is the ratio of real power to apparent power in an AC circuit.
It is a measure of how efficiently electrical power is being used.
It ranges from 0 to 1, with 1 being the most efficient.
A low power factor can result in higher energy costs and equipment damage.
Capacitors can be used to improve power factor.
Example: A motor with a power factor of 0.8 requires 1.25 times more current than a motor with a power fa
I applied via Referral and was interviewed in Feb 2021. There was 1 interview round.
M-25 Grade concrete is a type of concrete with a compressive strength of 25 megapascals (MPa).
M-25 Grade concrete is commonly used in construction projects.
The ratio of M-25 Grade concrete is 1:1:2, which means 1 part cement, 1 part fine aggregate (sand), and 2 parts coarse aggregate (stone).
The mix proportion of M-25 Grade concrete is designed to achieve a desired strength and durability for the specific application.
F...
The number of bricks required in 1 cubic meter depends on the size of the bricks and the thickness of the mortar joints.
The size of the bricks and the thickness of the mortar joints determine the number of bricks needed.
Standard brick sizes are commonly used in construction.
For example, if the size of the brick is 200mm x 100mm x 75mm and the thickness of the mortar joint is 10mm, the calculation would be as follows:
- ...
I applied via Walk-in and was interviewed before Sep 2023. There was 1 interview round.
I have 5 years of experience working as a Site Supervisor in construction projects.
5 years of experience as a Site Supervisor
Managed multiple construction projects simultaneously
Ensured adherence to safety regulations and project timelines
Coordinated with subcontractors and communicated with clients
Implemented cost-saving measures without compromising quality
Yes, I am always open to change and adapt to new situations in order to improve efficiency and effectiveness.
I believe in continuous improvement and am willing to change my approach if it leads to better results
I am open to feedback and suggestions from team members and stakeholders
I have successfully implemented new processes and procedures in the past to enhance productivity
I applied via Walk-in and was interviewed in Nov 2024. There were 2 interview rounds.
What type of work termite tretment.
For Pre Construction Anti Termite Treatment. The surface of the ground should be dry and clean. The chemical should be injected three times in a certain order into the ground. Firstly, the earth’s surface shall be drilled in 12mm diameter and 300mm deep at 150mm intervals below the PPC. Post construction. plinth area dril in home 45 degree angel 10" hole and gave 8/10" distance & wood area .
Spray continues inside the room. Drain area spray for anti larva treatment. Garden and out site for big fogger.
Wash bedding, clothes, and blankets in hot water . and one chemical ( propoxure20%) best work for bed bugs and cockroach and household insecticide.
I applied via Naukri.com and was interviewed before Jun 2021. There were 3 interview rounds.
I applied via Referral and was interviewed before Aug 2021. There were 2 interview rounds.
I applied via Referral and was interviewed before Aug 2021. There was 1 interview round.
I appeared for an interview before Feb 2024.
The role of APFC (Automatic Power Factor Controller) is to maintain the power factor of electrical systems by automatically switching capacitors in and out of the circuit.
APFC monitors the power factor of the system and activates or deactivates capacitors accordingly.
It helps in reducing electricity bills by improving power factor and reducing reactive power consumption.
APFC ensures efficient utilization of electrical ...
Transformation ratio is the ratio of the number of turns in the primary winding to the number of turns in the secondary winding of a transformer.
Transformation ratio determines the voltage transformation between the primary and secondary windings of a transformer.
It is calculated as the ratio of the number of turns in the primary winding to the number of turns in the secondary winding.
For example, if a transformer has ...
I applied via Referral and was interviewed before Nov 2020. There were 3 interview rounds.
based on 1 interview
Interview experience
Principal Analyst
28
salaries
| ₹8.8 L/yr - ₹20.6 L/yr |
Senior Analyst
10
salaries
| ₹5.4 L/yr - ₹12.6 L/yr |
Analyst
7
salaries
| ₹5.2 L/yr - ₹11.1 L/yr |
Driver
5
salaries
| ₹2.5 L/yr - ₹5 L/yr |
Ptp Analyst
4
salaries
| ₹5.2 L/yr - ₹8.5 L/yr |
Sodexo
ISS Facility Services
BVG India
Leadec India