I applied via Referral and was interviewed before Oct 2023. There was 1 interview round.
Calibration parameters for HPLC include wavelength accuracy, linearity, resolution, and peak symmetry.
Wavelength accuracy: Ensuring the detector is accurately measuring the wavelength of the sample.
Linearity: Verifying that the detector response is linear over a range of concentrations.
Resolution: Assessing the ability of the HPLC system to separate peaks of interest.
Peak symmetry: Checking the symmetry of peaks to ens
Empower3 software uses various integration methods and tools for data analysis.
Empower3 software offers integration methods such as peak detection, peak integration, and peak area calculation.
Tools like Empower 3 Chromatography Data Software are commonly used for integration in chromatography analysis.
Integration methods in Empower3 software help in accurately quantifying compounds in samples.
Empower3 software allows f...
OOS investigation procedure involves identifying, documenting, and resolving deviations in quality control processes.
Initiate investigation promptly upon observing an OOS result
Document all relevant information including sample details, testing procedures, and environmental conditions
Conduct root cause analysis to determine the reason for the OOS result
Implement corrective and preventive actions to address the root cau...
Yes, I am currently handling Out of Trend (OOT) investigations in my role as QC Executive.
Yes, I have experience in identifying OOT results and conducting thorough investigations to determine the root cause.
I have worked on implementing corrective and preventive actions to prevent future OOT occurrences.
I have also collaborated with cross-functional teams to address OOT issues and ensure compliance with regulatory requ
Deviation in quality control refers to a departure from standard procedures or specifications. There are two main types of deviations - major and minor.
Deviation is a departure from standard procedures or specifications
Major deviations are significant and can impact product quality or safety
Minor deviations are less significant and may not impact product quality or safety
Examples of deviations include equipment malfunc
posted on 16 Aug 2021
I applied via Company Website and was interviewed in Feb 2021. There were 5 interview rounds.
I applied via Pharma wisdom and was interviewed before Apr 2020. There were 3 interview rounds.
The challenge test of a machine is a test to determine its capabilities and limitations.
The challenge test should be designed to push the machine to its limits.
It should be conducted in a controlled environment to ensure safety.
Examples of challenge tests include stress tests, endurance tests, and performance tests.
The results of the challenge test can be used to improve the machine's design and performance.
I applied via Walk-in and was interviewed before Sep 2020. There were 4 interview rounds.
FFS machine stands for Form-Fill-Seal machine, which is a packaging machine used to form, fill, and seal products in various industries.
FFS machine is commonly used in industries such as food and beverage, pharmaceuticals, and cosmetics.
It is an automated machine that can produce packaging materials on-site.
The machine forms a package from a flat roll of film, fills it with the product, and then seals it.
FFS machines c...
Kaizen is a Japanese term for continuous improvement. It involves making small, incremental changes to improve processes and systems.
Kaizen is a philosophy that focuses on continuous improvement in all aspects of an organization.
It involves identifying areas for improvement, making small changes, and then evaluating the results.
Kaizen can be applied to any process or system, from manufacturing to healthcare.
Examples of...
Transformers are electrical devices that transfer energy between two or more circuits through electromagnetic induction.
Transformers are used to increase or decrease voltage levels in electrical circuits
They consist of two coils of wire wrapped around a magnetic core
The primary coil is connected to the input voltage and the secondary coil to the output load
Step-up transformers increase voltage while step-down transform...
posted on 7 Aug 2020
I applied via Naukri.com and was interviewed in Feb 2020. There were 3 interview rounds.
Water content mechanism can be found through various methods and is important for various reasons.
Water content can be measured through techniques such as gravimetric analysis, Karl Fischer titration, and moisture analyzers.
Water content is important in industries such as food, pharmaceuticals, and cosmetics to ensure product quality and stability.
Water content is also important in environmental studies to understand t...
Developing HPLC methods involves selecting appropriate columns and optimizing parameters.
Choose a suitable column based on the analyte's properties and the separation goal.
Optimize parameters such as mobile phase composition, flow rate, and temperature.
Validate the method by assessing its selectivity, sensitivity, accuracy, and precision.
Common column types include C18, C8, and phenyl.
Other factors to consider include ...
Carbon loading in column refers to the amount of carbon used in the stationary phase of a chromatography column. Endcapping is a process to block the remaining silanol groups on the surface of the stationary phase.
Carbon loading is typically expressed as a percentage of the total weight of the stationary phase.
Higher carbon loading can improve the selectivity and retention of certain analytes.
Endcapping is important to...
I was interviewed in Feb 2017.
I applied via Recruitment Consultant and was interviewed in Feb 2021. There were 3 interview rounds.
I applied via Referral and was interviewed before Feb 2021. There were 2 interview rounds.
Reactors are vessels used for chemical reactions. Different types include batch, continuous, stirred tank, and plug flow reactors.
Batch reactors are used for small-scale production and testing.
Continuous reactors are used for large-scale production and can operate continuously for long periods of time.
Stirred tank reactors are used for mixing and heating/cooling of liquids.
Plug flow reactors are used for reactions that...
I applied via Company Website and was interviewed in Mar 2020. There were 3 interview rounds.
SAP activity refers to the use of SAP software for business operations and management.
SAP activity involves using SAP software for various business functions such as finance, human resources, supply chain management, and customer relationship management.
It helps organizations streamline their processes, improve efficiency, and make data-driven decisions.
Examples of SAP activity include creating financial reports, manag...
pH activity refers to the measurement of acidity or alkalinity of a solution.
pH activity is measured on a scale of 0-14, with 7 being neutral, below 7 being acidic, and above 7 being alkaline
It is important in various fields such as chemistry, biology, and environmental science
For example, pH activity is used to determine the acidity of soil for agriculture, the pH of water for aquatic life, and the pH of blood for med
The pH value decreases when acid is added and increases when alkali is added.
Acids release hydrogen ions (H+) when dissolved in water, which increases the concentration of H+ ions and lowers the pH value.
Alkalis release hydroxide ions (OH-) when dissolved in water, which decreases the concentration of H+ ions and raises the pH value.
The pH scale ranges from 0 to 14, with 7 being neutral. Values below 7 are acidic, and ...
Chemical reaction between sodium and chlorine
Sodium (Na) reacts with chlorine (Cl) to form sodium chloride (NaCl)
The reaction is exothermic and releases energy in the form of heat and light
The balanced chemical equation is 2Na + Cl2 -> 2NaCl
I applied via Company Website and was interviewed in Jan 2022. There were 3 interview rounds.
Sodium cyanide should be handled with extreme caution due to its highly toxic nature.
Wear appropriate personal protective equipment (PPE) such as gloves, goggles, and respirators.
Store sodium cyanide in a secure, well-ventilated area away from incompatible materials.
Use proper handling techniques such as avoiding skin contact and not inhaling dust or fumes.
Dispose of sodium cyanide properly according to local regulatio...
based on 1 interview
Interview experience
Senior Executive
63
salaries
| ₹0 L/yr - ₹0 L/yr |
Executive
58
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
34
salaries
| ₹0 L/yr - ₹0 L/yr |
Junior Manager
10
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Chemist
8
salaries
| ₹0 L/yr - ₹0 L/yr |
Biocon Limited
Syngene International
Dr. Reddy's
Sun Pharmaceutical Industries