Preventive and corrective maintenance of various electrical equipment including breakers, motors, transformers, and relays.
Perform regular maintenance on high and low voltage breakers, motors, and transformers.
Test and calibrate various protection relays for motors, transformers, and generators.
Conduct transformer oil BDV test, thermal scanning, and earth fault and prediction tests.
Terminate high voltage motors, instal...
Preventive and corrective maintenance of various electrical equipment including breakers, motors, transformers, and relays.
Perform regular maintenance tasks on high and low voltage breakers, motors, and transformers.
Test and calibrate protection relays for motors, transformers, and generators.
Conduct transformer oil BDV tests, thermal scanning, and earth fault and prediction tests.
Terminate high voltage motors, install...
Preventive and corrective maintenance of various electrical equipment including breakers, motors, transformers, switches, relays, and testing/calibration of protections.
Preventive maintenance of H.V & LV breakers, motors, transformers, switches, etc.
Corrective maintenance of HV/MV/LV switchgears, breakers, cubicles, etc.
Testing and calibration of various protection relays for motors, transformers, generators.
Transforme...
I applied via Recruitment Consultant and was interviewed in Oct 2021. There was 1 interview round.
posted on 11 Jan 2024
I applied via Company Website and was interviewed in Feb 2024. There was 1 interview round.
Ohm's law states that the current flowing through a conductor is directly proportional to the voltage applied across it, and inversely proportional to the resistance of the conductor.
Ohm's law is represented by the formula V = I * R, where V is voltage, I is current, and R is resistance.
It helps in calculating the current, voltage, or resistance in a circuit when the other two values are known.
For example, if a circuit...
I applied via Recruitment Consultant and was interviewed in May 2021. There were 3 interview rounds.
Stall in a motor refers to a condition where the motor stops rotating despite the presence of power supply.
Stall occurs when the motor is overloaded or when there is a mechanical obstruction preventing the motor from rotating.
It can also occur when the motor is underpowered or when there is a fault in the electrical system.
Stall can cause damage to the motor and other components if not addressed promptly.
Examples of mo...
UPS stands for Uninterruptible Power Supply. It is an electrical device that provides emergency power to a load when the input power source fails.
UPS has three main components: battery, inverter, and rectifier.
The battery provides backup power during a power outage.
The rectifier converts AC power to DC power to charge the battery.
The inverter converts DC power from the battery to AC power to supply the load.
UPS also ha...
Interview experience
Safety Officer
11
salaries
| ₹0.7 L/yr - ₹4.4 L/yr |
QC Inspector
7
salaries
| ₹11 L/yr - ₹20 L/yr |
HSE Officer
6
salaries
| ₹6.3 L/yr - ₹12.9 L/yr |
QA QC Welding Inspector
5
salaries
| ₹17.9 L/yr - ₹20 L/yr |
QC Welding Inspector
5
salaries
| ₹19 L/yr - ₹24 L/yr |
Tata Group
Reliance Industries
Adani Group
Mahindra & Mahindra