I applied via Recruitment Consultant and was interviewed in Sep 2020. There was 1 interview round.
Top trending discussions
I applied via Company Website
Electrician test and all questions
I applied via Instahyre and was interviewed before May 2023. There were 2 interview rounds.
The speed difference between stator's rotating magnetic field and rotor's rmf is called slip.
The slip is necessary for inducing current in the rotor and producing torque.
The slip is typically around 1-3% in most induction motors.
Higher slip values can indicate issues with the motor such as overload or mechanical problems.
An induction motor is a type of AC motor where power is supplied to the rotor by electromagnetic induction.
Induction motors are commonly used in various applications such as industrial machinery, pumps, fans, and compressors.
They do not require brushes to transfer power to the rotor, making them more reliable and maintenance-free compared to brushed DC motors.
The speed of an induction motor is determined by the frequen...
Synchronisation is the process of coordinating multiple systems or devices to work together in harmony.
Synchronisation ensures that different components or processes are aligned in time.
It is commonly used in electrical systems to ensure that multiple generators are running in phase with each other.
In data communication, synchronisation is important for ensuring that data is transmitted and received at the correct timi...
The speed of a rotor with respect to the stator magnetic field in an induction motor is known as slip speed.
The slip speed is the difference between the synchronous speed of the rotating magnetic field in the stator and the actual speed of the rotor.
It is necessary for the rotor to operate at a speed slightly slower than the synchronous speed in order to induce current and generate torque.
The slip speed allows the roto...
Slip is the difference between synchronous speed and actual rotor speed in an induction motor. Per unit slip is the slip expressed as a fraction of synchronous speed.
Slip is the difference between synchronous speed (speed of the rotating magnetic field) and the actual rotor speed in an induction motor.
Per unit slip is the slip expressed as a fraction of synchronous speed, typically denoted as a percentage.
For example, ...
Single phase and three phase are two types of electrical power distribution systems.
Single phase has one live conductor and one neutral conductor, while three phase has three live conductors and one neutral conductor.
Single phase is commonly used in residential and small commercial applications, while three phase is used in industrial and large commercial applications.
Single phase power supply is suitable for low power...
R, Y, B phases are the three phases of AC power supply. They differ in their phase angle and voltage level.
R phase has a phase angle of 0 degrees and is usually connected to the red wire.
Y phase has a phase angle of 120 degrees and is usually connected to the yellow wire.
B phase has a phase angle of 240 degrees and is usually connected to the blue wire.
The voltage level of each phase is the same, but they are out of ph...
In series, voltage adds up while current remains the same. In parallel, voltage remains the same while current adds up.
In series, batteries are connected end-to-end, positive to negative. In parallel, batteries are connected positive to positive and negative to negative.
Series connection increases voltage but does not increase current. Parallel connection increases current but does not increase voltage.
Series connectio...
Periodic maintenance of batteries is crucial for their longevity and optimal performance.
Check the battery terminals for corrosion and clean them if necessary
Inspect the battery case for any cracks or damage
Ensure that the battery is securely fastened in place
Check the electrolyte level and top up with distilled water if required
Test the battery voltage and recharge if necessary
A faulty battery can be identified by checking its voltage, capacity, and physical appearance.
Check the voltage of the battery using a multimeter
Test the capacity of the battery using a battery tester
Inspect the physical appearance of the battery for any signs of damage or leakage
Check the battery terminals for corrosion or loose connections
Compare the battery's performance to its specifications
FUSE, MCB, ELCB, and RCCB are all electrical protection devices, but they differ in their functions and applications.
FUSE is a simple device that protects electrical circuits from overloading or short-circuiting by melting and breaking the circuit.
MCB (Miniature Circuit Breaker) is an automatic switch that trips and cuts off the power supply when there is an overload or short-circuit.
ELCB (Earth Leakage Circuit Breaker...
A DOL starter is a direct online motor starter that provides full voltage to the motor.
Consists of a contactor, overload relay, and start/stop buttons
The contactor connects the motor to the power supply
The overload relay protects the motor from overloading
The start/stop buttons control the on/off function of the motor
Used for small motors with low starting current
Not suitable for large motors or motors with high starti
posted on 25 Jan 2025
I appeared for an interview in Dec 2024.
posted on 22 Dec 2024
I applied via Approached by Company and was interviewed in Nov 2024. There were 2 interview rounds.
12 th & Electricale Engineer Diploma
I applied via Referral and was interviewed before Sep 2023. There were 4 interview rounds.
Conduct Theoretical Test.
Practical Test and group dissertation with electrical
Current is the flow of electric charge, measured in Amperes, while voltage is the force that drives the current, measured in Volts.
Current is the rate of flow of electric charge in a circuit
Voltage is the electrical potential difference that drives the current
Current is measured in Amperes (A)
Voltage is measured in Volts (V)
Ohm's Law states that V = I * R, where V is voltage, I is current, and R is resistance
Types of motors include AC motors, DC motors, synchronous motors, asynchronous motors, stepper motors, and servo motors.
AC motors: Alternating current motors commonly used in household appliances and industrial applications.
DC motors: Direct current motors used in applications where speed control is important.
Synchronous motors: Maintain a constant speed and are used in applications like clocks and timers.
Asynchronous ...
AC and DC are two types of electrical current with different characteristics and applications.
AC stands for alternating current, which periodically changes direction and magnitude.
DC stands for direct current, which flows in one direction at a constant voltage.
AC is commonly used in household appliances and power distribution systems.
DC is often used in electronics, such as batteries and computer power supplies.
Solar field presentation
posted on 17 Feb 2025
Three-phase voltage is a type of electrical power transmission that utilizes three alternating currents.
Three-phase voltage consists of three alternating currents that are 120 degrees out of phase with each other.
It is commonly used in industrial and commercial applications for its efficiency and power distribution capabilities.
The voltage levels for three-phase systems can vary depending on the application, with commo...
The process for entering single-phase voltage involves connecting the voltage source to the load through a single conductor.
Connect the single-phase voltage source to the load through a single conductor
Ensure proper insulation and grounding for safety
Check the voltage level using a multimeter before connecting the load
Make sure the load is compatible with the voltage rating
posted on 27 May 2024
I applied via Naukri.com and was interviewed before May 2023. There were 2 interview rounds.
A slip ring is an electrical component used to transfer power and electrical signals from a stationary to a rotating structure.
Allows for continuous rotation without tangling wires
Commonly used in electromechanical systems like motors, generators, and wind turbines
Consists of stationary brushes and rotating conductive rings
Helps in transmitting power, data, and signals across rotating interfaces
Unit slip is the difference between synchronous speed and rotor speed in an induction motor.
Unit slip is expressed as a fraction or percentage.
It is used to calculate the rotor speed of an induction motor.
Unit slip is necessary for determining the torque and efficiency of the motor.
For example, if the synchronous speed of a motor is 1800 RPM and the rotor speed is 1750 RPM, the unit slip would be 0.0278 or 2.78%.
based on 4 reviews