Q1. If fault occurred how to detect from where fault occurred.
To detect the source of a fault, a systematic approach is required.
Start by identifying the symptoms of the fault
Trace the steps leading up to the fault
Use diagnostic tools to pinpoint the source of the fault
Check for any related issues that may have caused the fault
Document the findings for future reference
Q2. What is difference between 4 wire and 2 wire.
4 wire and 2 wire are types of electrical wiring used for different purposes.
4 wire is used for three-phase power distribution while 2 wire is used for single-phase power distribution.
4 wire has four conductors - three phase conductors and one neutral conductor, while 2 wire has two conductors - one live and one neutral.
4 wire is used in industrial and commercial settings while 2 wire is used in residential settings.
4 wire is more expensive and complex to install than 2 wire....read more
Q3. How you can connect signals of pump to DCS.
Signals of pump can be connected to DCS through analog or digital inputs.
Analog inputs can be used to measure the pump's flow rate, pressure, and temperature.
Digital inputs can be used to monitor the pump's status, such as on/off or fault conditions.
The signals can be wired directly to the DCS or through a remote I/O module.
Proper grounding and shielding techniques should be followed to avoid interference and noise.
Examples of DCS systems that can connect to pump signals incl...read more
Q4. How thermocouple temp is transmitted to DCS.
Thermocouple temp is transmitted to DCS through analog signals or digital communication protocols.
Thermocouple generates a voltage signal proportional to temperature
This signal is amplified and transmitted to DCS through analog signals or digital communication protocols like HART, Modbus, etc.
Analog signals are converted to digital signals using analog-to-digital converters (ADC)
The DCS receives the signal and displays the temperature value on the operator interface
Q5. Why we use shuttering oil on surfaces of shuttering
Shuttering oil is used to prevent concrete from sticking to the surface of the shuttering.
Shuttering oil is applied to the surface of the shuttering to prevent the concrete from sticking to it.
It helps in easy removal of the shuttering after the concrete has set.
It also helps in achieving a smooth finish on the concrete surface.
Using shuttering oil reduces the chances of damage to the shuttering during removal.
Different types of shuttering oils are available for different typ...read more
Q6. What is the rating of HT panel
The rating of HT panel depends on its voltage and current capacity.
HT panel rating is determined by its voltage and current capacity
It can range from 11kV to 33kV or higher
The current capacity can range from a few hundred amps to several thousand amps
The rating is usually mentioned on the panel itself or in the technical specifications
It is important to ensure that the panel rating is suitable for the intended application
Q7. What is fail safe circuit.
A fail-safe circuit is a safety mechanism that ensures a system will shut down in the event of a failure or malfunction.
Fail-safe circuits are commonly used in industries such as aviation, automotive, and nuclear power.
They are designed to prevent accidents or damage to equipment by shutting down the system if a fault is detected.
Examples of fail-safe circuits include emergency brakes in cars and automatic shutdown systems in nuclear power plants.
Q8. How silica transmitter works.
Silica transmitter measures the level of silica in water by using a colorimetric method.
Silica reacts with molybdate ions in an acidic solution to form a yellow complex.
The intensity of the yellow color is proportional to the amount of silica present.
The color is measured by a photometer and converted into a digital signal.
The signal is then transmitted to a control system for monitoring and control purposes.
Q9. How to calculate scaffolding quantities.
Scaffolding quantities can be calculated by determining the height, length, and width of the area to be covered.
Measure the height, length, and width of the area to be covered
Determine the type of scaffolding needed
Calculate the number of scaffolding units required
Consider the weight capacity and safety regulations
Adjust the quantities based on the complexity of the project