Facility Executive - Technical
Facility Executive - Technical Interview Questions and Answers for Freshers
Q1. What is the safety prications of before working working
Safety precautions before working
Conduct a thorough risk assessment of the work area
Ensure all necessary personal protective equipment (PPE) is available and worn
Implement proper training and education on safety procedures
Inspect and maintain tools and equipment regularly
Establish emergency response plans and procedures
Promote a culture of safety and encourage reporting of hazards or incidents
Q2. Which type of fire Extingusher used in server room
A clean agent fire extinguisher is typically used in server rooms.
Clean agent fire extinguishers are designed to suppress fires without leaving residue or damaging sensitive equipment.
They use chemicals like halon, carbon dioxide, or clean agents like FM-200 or Novec 1230.
These extinguishers are effective in suppressing fires involving electrical equipment and are safe for use in server rooms.
It is important to consult local fire codes and regulations to determine the specifi...read more
Q3. What is difference between chiller and PAC
A chiller is a refrigeration system used to cool large spaces, while a PAC (Portable Air Conditioner) is a compact unit used for localized cooling.
Chillers are typically used in commercial or industrial settings to cool large areas such as office buildings or factories.
PACs are smaller and more portable, designed to cool specific areas or rooms.
Chillers use a refrigeration cycle to remove heat from the air or water, while PACs use a compressor and refrigerant to cool the air....read more
Q4. What are the checks and frequency of DG
Regular checks and maintenance are essential for ensuring the proper functioning of DG (Diesel Generator) systems.
Daily visual inspections for leaks, damages, and loose connections.
Weekly checks for fuel levels, coolant levels, and battery condition.
Monthly load testing to ensure the generator can handle the required load.
Annual maintenance including oil and filter changes, spark plug replacement, and thorough cleaning.
Regular checks of safety features like emergency stop but...read more
Q5. What are the safety measurements of UPS
UPS (Uninterruptible Power Supply) safety measures include surge protection, battery backup, and automatic voltage regulation.
Surge protection safeguards electronic devices from power surges or spikes.
Battery backup provides temporary power during outages, preventing data loss or equipment damage.
Automatic voltage regulation stabilizes voltage levels, protecting equipment from fluctuations.
UPS systems may have audible alarms, visual indicators, and remote monitoring for safet...read more
Q6. What is the UPS and Types of UPS
UPS stands for Uninterruptible Power Supply. There are three types of UPS: standby, line-interactive, and online.
UPS stands for Uninterruptible Power Supply.
UPS provides backup power to critical equipment during power outages or fluctuations.
The three types of UPS are standby, line-interactive, and online.
Standby UPS switches to battery power when the main power source fails.
Line-interactive UPS regulates voltage fluctuations and switches to battery power when necessary.
Onlin...read more
Share interview questions and help millions of jobseekers 🌟
Q7. How to maintan the Trasformer
To maintain a transformer, regular inspections, cleaning, and testing are necessary.
Perform regular visual inspections to check for any signs of damage or leaks.
Clean the transformer regularly to remove dust, dirt, and debris.
Test the transformer's insulation resistance to ensure it is within acceptable limits.
Monitor the transformer's temperature and oil levels regularly.
Perform oil analysis to detect any potential issues or contaminants.
Ensure proper ventilation and cooling...read more
Q8. What is 52 week shadule
A 52-week schedule is a plan that outlines tasks, events, or milestones for each week of a year.
A 52-week schedule helps in organizing and managing tasks throughout the year.
It can be used in various industries such as project management, event planning, and manufacturing.
Each week of the schedule may include specific goals, deadlines, or activities.
Examples of 52-week schedules include construction project timelines, marketing campaign calendars, and maintenance plans.
Facility Executive - Technical Jobs
Q9. What is the 6S
6S is a workplace organization methodology that focuses on creating a clean, efficient, and safe environment.
6S stands for Sort, Set in Order, Shine, Standardize, Sustain, and Safety.
It is derived from the 5S methodology and adds an additional focus on safety.
Sort involves removing unnecessary items from the workplace.
Set in Order involves organizing and arranging necessary items in a logical manner.
Shine refers to cleaning and maintaining the workplace.
Standardize involves c...read more
Q10. Types of chiller
There are several types of chillers used in facilities, including air-cooled, water-cooled, absorption, and centrifugal chillers.
Air-cooled chillers use air to remove heat from the refrigerant.
Water-cooled chillers use water to remove heat from the refrigerant.
Absorption chillers use a heat source, such as natural gas or steam, to drive the refrigeration cycle.
Centrifugal chillers use centrifugal force to compress the refrigerant and remove heat.