The least count of a vernier caliper is the smallest measurement that can be read on the scale.
The least count is determined by the number of divisions on the vernier scale and the main scale.
It is usually expressed in fractions of a millimeter or inch.
For example, a vernier caliper with 20 divisions on the vernier scale and 1mm on the main scale has a least count of 0.05mm.
The least count is important for accurate mea...
Top trending discussions
I applied via Walk-in and was interviewed in Mar 2022. There were 2 interview rounds.
I applied via Company Website
TTR stands for Total Thickness Range and is required for powder coating process to ensure proper adhesion and durability.
TTR is the range of thickness of the substrate and any coatings applied to it
It is important for powder coating as it ensures proper adhesion and durability
If the TTR is too large, the coating may not adhere properly or may crack and peel over time
Examples of substrates with varying TTR include alumi
Detection and prevention poka-yoke refers to the use of techniques to identify and prevent errors in a process.
Poka-yoke is a Japanese term for mistake-proofing
Detection poka-yoke involves identifying errors as they occur
Prevention poka-yoke involves designing processes to prevent errors from occurring
Examples of poka-yoke include using checklists, color-coding, and physical barriers
Poka-yoke can improve quality, reduc
Decrease in pH can occur due to various factors in conversion coating.
Decrease in pH can be caused by the addition of an acid or acidic solution.
Presence of reactive metals in the coating can lead to a decrease in pH.
Contamination by organic materials or impurities can also lower the pH.
Chemical reactions during the conversion coating process may result in pH decrease.
Examples of conversion coatings include phosphating
To prepare 0.1 N H2SO4 & NaOH, calculate the required amount of solute and dissolve it in distilled water.
Calculate the molar mass of H2SO4 and NaOH
Determine the required amount of solute using the formula: N = (W/M) x (1000/V)
Dissolve the calculated amount of solute in distilled water to make 1 liter of solution
Standardize the solution using a primary standard
Use a burette to measure the volume of solution needed for
To cross verify 0.1 normality H2SO4, use a standard solution of NaOH and an indicator.
Prepare a standard solution of NaOH of known concentration.
Add a few drops of an indicator such as phenolphthalein to the H2SO4 solution.
Titrate the H2SO4 solution with the NaOH solution until the endpoint is reached.
The endpoint is when the indicator changes color, indicating that all the H2SO4 has reacted with the NaOH.
Calculate the...
Prepare a pH buffer solution as per defined standard in tablet.
Determine the required pH value and buffer capacity
Select the appropriate buffer system and calculate the required amounts of buffer components
Dissolve the buffer components in water and adjust the pH as necessary
Check the pH and adjust if necessary
Filter the solution and store in a clean container
Use a calibrated pH meter to verify the pH of the solution
I applied via Recruitment Consulltant and was interviewed before Oct 2022. There were 3 interview rounds.
A relay holding circuit diagram is used to keep the relay in the energized state even after the control signal is removed.
The circuit typically includes a holding contact that maintains the relay coil energized.
A latching relay can also be used for holding without continuous power supply.
Examples: ladder logic diagram with a holding contact, latching relay circuit diagram.
PNP and NPN are types of bipolar junction transistors commonly used in electronic circuits.
PNP transistor has a layer of N-type semiconductor between two layers of P-type semiconductor, while NPN transistor has a layer of P-type semiconductor between two layers of N-type semiconductor.
In a PNP transistor, current flows from the emitter to the base and then to the collector, while in an NPN transistor, current flows fro...
There are various types of sensors used for different purposes.
Temperature sensors (e.g. thermocouples, thermistors)
Pressure sensors (e.g. piezoelectric sensors)
Motion sensors (e.g. accelerometers, gyroscopes)
Proximity sensors (e.g. ultrasonic sensors)
Light sensors (e.g. photodiodes, phototransistors)
PLC stands for Programmable Logic Controller, which is a digital computer used for automation of electromechanical processes.
PLC is used to control machinery in manufacturing processes, such as assembly lines, robotic devices, or any activity that requires high reliability control.
It is programmed using a specialized computer language, typically ladder logic or function block diagram.
PLCs are commonly used in industrie...
I applied via Naukri.com and was interviewed before Aug 2020. There was 1 interview round.
I was interviewed before May 2021.
I applied via Naukri.com and was interviewed before Aug 2021. There were 2 interview rounds.
Aptitude test content core electrical maintenance questions
I applied via Walk-in and was interviewed before Mar 2021. There was 1 interview round.
The least count of a Vernier Caliper is the smallest measurement that can be accurately read on the scale.
The least count is determined by the number of divisions on the main scale and the Vernier scale.
It is calculated by dividing the smallest division on the main scale by the total number of divisions on the Vernier scale.
For example, if the smallest division on the main scale is 0.1 mm and the Vernier scale has 10 d...
CMM stands for Capability Maturity Model. It is a framework used to assess and improve the maturity of an organization's software development processes.
CMM is a model developed by the Software Engineering Institute (SEI) at Carnegie Mellon University.
It provides a set of best practices and guidelines for organizations to follow in order to improve their software development processes.
CMM consists of five levels of matu...
Graduate Engineer Trainee (Get)
32
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Engineer
25
salaries
| ₹0 L/yr - ₹0 L/yr |
Production Engineer
21
salaries
| ₹0 L/yr - ₹0 L/yr |
Quality Engineer
18
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Production Engineer
15
salaries
| ₹0 L/yr - ₹0 L/yr |
Jamna Auto Industries
Rane (Madras)
Samvardhana Motherson Group
Bharat Forge