Condenser vacuum gradually lowering trend may be due to air leakage, cooling water temperature increase, or decrease in cooling water flow rate.
Air leakage in the condenser system can lead to a decrease in vacuum levels.
Increase in cooling water temperature can reduce the efficiency of the condenser, causing vacuum levels to drop.
Decrease in cooling water flow rate can also impact the condenser's ability to maintain pr
I come from a family of engineers and want to explore new opportunities for growth and development.
Family background includes engineers, inspiring me to pursue a career in engineering
Seeking new challenges and opportunities for growth
Looking for a more dynamic work environment
Interested in expanding my skill set and knowledge in a different setting
I applied via Referral and was interviewed in Jul 2024. There was 1 interview round.
Bearings and bearing maintenance and assembly
I applied via Naukri.com and was interviewed in May 2020. There were 3 interview rounds.
posted on 11 Apr 2022
I applied via Approached by Company and was interviewed before Apr 2021. There were 2 interview rounds.
Trip oil procedure is a process of shutting down a machine or equipment in case of an emergency or abnormal condition.
The procedure involves stopping the flow of oil to the machine or equipment.
This is done to prevent damage to the machine or equipment.
The trip oil system is usually automated and activated by sensors that detect abnormal conditions.
The system can also be manually activated by an operator in case of an ...
The steam drum is a component of a boiler that stores and distributes steam.
It is a cylindrical vessel located at the top of the boiler.
It separates steam from water and distributes it to the rest of the boiler.
It also serves as a reservoir for the boiler feedwater.
It is equipped with various instruments to monitor and control the boiler's operation.
Coal analysis is the process of determining the composition and properties of coal.
Coal analysis involves measuring the moisture content, ash content, volatile matter, and fixed carbon content of coal.
It also includes determining the heating value, sulfur content, and other impurities present in the coal.
The results of coal analysis are used to determine the suitability of coal for different applications, such as power...
I was interviewed in May 2024.
Bearings and bearing service and data maintain CAL skin pass mill a
I applied via Company Website and was interviewed before Apr 2020. There were 3 interview rounds.
I was interviewed in Jul 2024.
I applied via Recruitment Consulltant and was interviewed in Sep 2024. There was 1 interview round.
The repeated burning of a 22 kW AOP motor CT cable may be due to overloading, short circuits, poor insulation, or incorrect cable sizing.
Check for overloading of the motor causing excessive heat in the cable
Inspect for short circuits in the motor or the wiring
Ensure proper insulation of the cable to prevent overheating
Verify if the cable size is appropriate for the motor's power requirements
Bypassing the CT of an AOP motor can lead to overcurrent and damage to the motor.
Bypassing the CT can result in the motor drawing excessive current.
This can lead to overheating of the motor windings.
Overcurrent can cause damage to the motor components.
It can also pose a safety risk due to potential electrical faults.
based on 1 review
Rating in categories
Assistant Manager
23
salaries
| ₹3.6 L/yr - ₹8.4 L/yr |
Senior Engineer
18
salaries
| ₹3.6 L/yr - ₹5.8 L/yr |
Assistant Engineer
16
salaries
| ₹1.2 L/yr - ₹4 L/yr |
Engineer
14
salaries
| ₹2.4 L/yr - ₹4 L/yr |
Mechanical Engineer
13
salaries
| ₹2.2 L/yr - ₹5 L/yr |
Tata Steel
JSW Steel
Steel Authority Of India
Jindal Steel and Power