Electrical protection measures for alternators
Overcurrent protection: Protects against excessive current flow
Overvoltage protection: Prevents damage from high voltage
Underfrequency protection: Guards against low frequency operation
Overtemperature protection: Prevents overheating of the alternator
Reverse power protection: Protects against power flowing back into the alternator
Earth fault protection: Detects and isolates...
Top trending discussions
I applied via Recruitment Consulltant and was interviewed in Sep 2024. There was 1 interview round.
The repeated burning of a 22 kW AOP motor CT cable may be due to overloading, short circuits, poor insulation, or incorrect cable sizing.
Check for overloading of the motor causing excessive heat in the cable
Inspect for short circuits in the motor or the wiring
Ensure proper insulation of the cable to prevent overheating
Verify if the cable size is appropriate for the motor's power requirements
Bypassing the CT of an AOP motor can lead to overcurrent and damage to the motor.
Bypassing the CT can result in the motor drawing excessive current.
This can lead to overheating of the motor windings.
Overcurrent can cause damage to the motor components.
It can also pose a safety risk due to potential electrical faults.
posted on 17 Oct 2024
I applied via Approached by Company and was interviewed in Apr 2024. There were 2 interview rounds.
Technical Question Related to Electrical and Instrumentation of rotary equipments.
Motor starters are devices used to start and stop electric motors safely and efficiently.
Motor starters control the flow of electricity to the motor, protecting it from overloads and short circuits.
They typically consist of a contactor, overload relay, and control devices like push buttons or switches.
Motor starters can be manual or automatic, with features like thermal overload protection and phase loss detection.
Exam...
Switchgears are electrical devices used to control, protect, and isolate electrical equipment in power systems.
Switchgears are used to control the flow of electricity in a power system.
They protect electrical equipment from overloads, short circuits, and other faults.
Switchgears can isolate faulty equipment to prevent damage to the rest of the system.
Examples of switchgears include circuit breakers, fuses, and disconne
posted on 30 Mar 2023
I applied via Company Website and was interviewed in Mar 2023. There were 2 interview rounds.
Yes I m only project engineering
I applied via Naukri.com and was interviewed in May 2020. There were 3 interview rounds.
posted on 7 Oct 2024
I applied via LinkedIn and was interviewed in Sep 2024. There was 1 interview round.
Synchronisation process of a plant involves matching the frequency, voltage, and phase angle of the incoming generator with the grid.
Ensure the generator frequency matches the grid frequency (50Hz or 60Hz).
Match the voltage levels of the generator with the grid.
Adjust the phase angle of the generator to synchronize with the grid.
Use synchronizing equipment like synchroscope or synchronizing lamps to ensure proper synch...
Alternator and transformer protection systems are essential for preventing damage and ensuring safe operation.
Alternator protection systems typically include overcurrent, overvoltage, and reverse power protection to safeguard the alternator from damage.
Transformer protection systems often involve differential protection, overcurrent protection, and temperature monitoring to prevent overheating and insulation breakdown.
...
I was interviewed in Jun 2023.
posted on 15 Sep 2023
I applied via Approached by Company and was interviewed in Mar 2023. There were 4 interview rounds.
posted on 27 Jul 2022
I applied via Referral and was interviewed in Jan 2022. There was 1 interview round.
based on 3 reviews
Rating in categories
Engineer
55
salaries
| ₹2.5 L/yr - ₹5.1 L/yr |
Assistant Manager
50
salaries
| ₹4.2 L/yr - ₹9 L/yr |
Assistant Engineer
50
salaries
| ₹1.7 L/yr - ₹4 L/yr |
Senior Engineer
47
salaries
| ₹3 L/yr - ₹7.2 L/yr |
Electrical Engineer
29
salaries
| ₹1.8 L/yr - ₹5.2 L/yr |
Tata Power
Adani Power
NTPC
Reliance Power