Filter interviews by
I am passionate about electrical engineering and eager to apply my skills in a practical setting.
Passionate about electrical engineering
Eager to apply skills in a practical setting
Excited about the opportunity to learn and grow in the field
Top trending discussions
posted on 12 Oct 2024
I applied via campus placement at PSG College of Technology, Coimbatore and was interviewed in Sep 2024. There were 3 interview rounds.
General knowlegde, Basic Aptitude, Domain Technical MCQ
Genx vs Genz, Altitude and comparsion
Components of a transformer include core, windings, and insulation.
Core: Provides a path for magnetic flux
Windings: Primary and secondary coils for inducing voltage
Insulation: Prevents short circuits and ensures safety
MCB is a miniature circuit breaker used for low voltage applications, while MCCB is a molded case circuit breaker used for higher currents and voltages.
MCB is designed for low voltage applications, typically up to 1000V, while MCCB is designed for higher currents and voltages, typically up to 2500V.
MCB is usually thermal-magnetic in operation, while MCCB can be thermal-magnetic or electronic trip units.
MCB is compact i...
Different types of breakers include circuit breakers, fuse breakers, and ground fault circuit interrupters.
Circuit breakers: Automatically switch off electrical circuits during abnormal conditions.
Fuse breakers: Use a fuse to interrupt the circuit when overloaded.
Ground fault circuit interrupters (GFCI): Detect imbalances in current flow to prevent electrical shocks.
Miniature circuit breakers (MCB): Provide protection ...
The test is very difficult you have to complete all 20 questions which consist GC , subject related
A wave trap is a device used in electrical engineering to prevent unwanted signals or frequencies from entering a system.
Wave traps are typically used in power systems to filter out specific frequencies that can cause interference.
They are designed to allow only desired signals to pass through while blocking unwanted signals.
Wave traps can be used in substations, transmission lines, and other electrical systems to impr...
Types of circuit breakers used in substations include air circuit breakers, oil circuit breakers, vacuum circuit breakers, and SF6 circuit breakers.
Air circuit breakers are commonly used in low voltage applications.
Oil circuit breakers are used in high voltage applications.
Vacuum circuit breakers are compact and reliable, suitable for medium voltage applications.
SF6 circuit breakers are used in high voltage substations
Global warming ,covid-19, current affairs
posted on 10 Jul 2024
posted on 19 Sep 2023
I applied via Naukri.com and was interviewed in Aug 2023. There were 2 interview rounds.
Communicate openly, provide support, set clear expectations, offer solutions
Communicate openly with designers to understand their challenges and concerns
Provide support and resources to help designers overcome tough times
Set clear expectations and goals to keep designers focused and motivated
Offer solutions and brainstorm ideas together to find the best way forward
I applied via Company Website and was interviewed in Apr 2023. There were 2 interview rounds.
Ohm's law states that the current through a conductor between two points is directly proportional to the voltage across the two points.
Ohm's law is represented by the equation I = V/R, where I is the current, V is the voltage, and R is the resistance.
It is named after Georg Simon Ohm, a German physicist who first formulated this law.
This law is applicable to all types of circuits, including DC and AC circuits.
It is use...
I applied via Walk-in and was interviewed in Mar 2023. There were 4 interview rounds.
The Loto system stands for Lockout/Tagout, a safety procedure used to ensure that dangerous machines are properly shut off and not started up again during maintenance or servicing.
Loto system involves locking the energy-isolating devices with individual lockout devices to prevent the machine from being turned on
Tagout involves placing a tag on the locked device to indicate that it should not be operated
Employees workin...
posted on 16 Dec 2023
based on 1 interview
Interview experience
Senior Engineer
177
salaries
| ₹10.9 L/yr - ₹32 L/yr |
Process Engineer
49
salaries
| ₹6 L/yr - ₹14.5 L/yr |
Piping Designer
48
salaries
| ₹4.4 L/yr - ₹16 L/yr |
Piping Engineer
40
salaries
| ₹6 L/yr - ₹15 L/yr |
Instrument Engineer
38
salaries
| ₹6 L/yr - ₹19.8 L/yr |
Larsen & Toubro Limited
Tata Projects
Punj Lloyd
Thermax Limited