Filter interviews by
I applied via LinkedIn and was interviewed before Jan 2022. There were 2 interview rounds.
TPM stands for Total Productive Maintenance. It is a maintenance strategy that aims to maximize equipment effectiveness and minimize downtime.
TPM involves the entire organization, not just maintenance personnel
The pillars of TPM are: 1) Autonomous Maintenance, 2) Planned Maintenance, 3) Quality Maintenance, 4) Training and Education, 5) Early Equipment Management
Autonomous Maintenance involves operators taking responsi...
PPM is calculated by dividing the number of defective units by the total number of units produced and multiplying by one million.
Determine the number of defective units
Determine the total number of units produced
Divide the number of defective units by the total number of units produced
Multiply the result by one million to get PPM
PPM = (Defective Units / Total Units) * 1,000,000
Top trending discussions
posted on 3 May 2019
I applied via Job Portal and was interviewed before Feb 2023. There were 2 interview rounds.
The count of vernier refers to the number of vernier scales present in a measurement tool.
Vernier calipers typically have one vernier scale for measuring length.
Micrometers may have multiple vernier scales for different units of measurement.
Counting the number of vernier scales can help determine the precision of the measurement tool.
Questions related to previous company experiences.
I applied via Company Website and was interviewed in Feb 2022. There were 4 interview rounds.
Refrigeration cycle is a thermodynamic cycle used in refrigerators and air conditioning systems to transfer heat from a low temperature reservoir to a high temperature reservoir.
Consists of four main components: compressor, condenser, expansion valve, and evaporator
Refrigerant is compressed in the compressor, then condensed in the condenser, expanded in the expansion valve, and evaporated in the evaporator
Heat is absor...
Refrigeration theory involves the transfer of heat from a low temperature region to a high temperature region using a refrigerant.
Refrigeration is based on the principles of thermodynamics, specifically the second law which states that heat naturally flows from a higher temperature to a lower temperature.
The refrigeration cycle consists of four main components: compressor, condenser, expansion valve, and evaporator.
The...
posted on 10 Feb 2024
A relay is an electrically operated switch that uses an electromagnet to mechanically control the switching action.
Relays are used to control high power or high voltage circuits with a low power signal.
They consist of an electromagnet, a set of contacts, and a spring.
When the coil of the electromagnet is energized, it creates a magnetic field that attracts the contacts, closing the circuit.
When the coil is de-energized...
posted on 23 Jun 2023
General knowledge, aptitude, reasoning, Technical Electrical
posted on 27 Jul 2023
I applied via Naukri.com and was interviewed in Jun 2023. There were 3 interview rounds.
Refrigeration cycle is a thermodynamic process used in refrigerators and air conditioners to transfer heat from a low temperature reservoir to a high temperature reservoir.
The refrigeration cycle consists of four main components: compressor, condenser, expansion valve, and evaporator.
The refrigerant absorbs heat from the indoor air in the evaporator, then it is compressed by the compressor to increase its temperature a...
I prioritize my decisions based on the impact on quality, customer satisfaction, and project deadlines.
I prioritize decisions by considering the potential impact on product quality.
I also take into account customer satisfaction and feedback when making decisions.
Project deadlines are important, so I prioritize tasks that are critical to meeting those deadlines.
I use data-driven analysis to prioritize decisions and focu...
based on 1 interview
Interview experience
based on 11 reviews
Rating in categories
Senior Engineer
69
salaries
| ₹3 L/yr - ₹7 L/yr |
Engineer
66
salaries
| ₹2.5 L/yr - ₹5.4 L/yr |
Assistant Manager
63
salaries
| ₹5.1 L/yr - ₹9.5 L/yr |
Quality Engineer
48
salaries
| ₹1.5 L/yr - ₹4 L/yr |
Production Engineer
19
salaries
| ₹2 L/yr - ₹4.5 L/yr |
Gandhi Automations
Kirloskar Pneumatic
Sulzer
Bharat Fritz Werner