Filter interviews by
I applied via Campus Placement and was interviewed before Feb 2023. There were 4 interview rounds.
45 minutes apptitude test online basis
pH is a measure of acidity or alkalinity in a solution. Sterilization is the process of killing or removing all microorganisms. Conductivity is the ability of a substance to conduct electricity. Sterilization temperature refers to the temperature required to kill microorganisms. Types of pH include acidic, alkaline, and neutral.
pH is a numeric scale used to specify the acidity or alkalinity of a solution.
Sterilization ...
I applied via Company Website
I applied via Referral and was interviewed before Aug 2020. There were 3 interview rounds.
Reliance Life Sciences interview questions for designations
I applied via Naukri.com and was interviewed in Oct 2020. There were 4 interview rounds.
I applied via Naukri.com and was interviewed in Nov 2020. There were 3 interview rounds.
posted on 31 Jan 2021
I applied via Naukri.com and was interviewed in Feb 2020. There were 3 interview rounds.
posted on 20 Nov 2024
They will give sample case study on real time based on company background
posted on 13 May 2024
I applied via Company Website and was interviewed before May 2023. There was 1 interview round.
HPLC is a technique used to separate, identify, and quantify components in a mixture based on their interactions with a stationary phase and a mobile phase.
HPLC stands for High-Performance Liquid Chromatography.
It involves the use of a stationary phase (usually a column packed with particles) and a mobile phase (liquid solvent).
The sample mixture is injected into the HPLC system and carried by the mobile phase through ...
Troubleshooting of HPLC involves identifying and resolving issues with the high-performance liquid chromatography system.
Check for leaks in the system and ensure proper connections
Inspect and clean the column to remove any blockages or contaminants
Verify the mobile phase composition and ensure it is prepared correctly
Calibrate and check the detector for proper functioning
Troubleshoot any issues with the pump, such as a...
Calibration of Balance pH KF
Calibration of a balance involves ensuring its accuracy and precision
pH calibration involves adjusting the pH meter to accurately measure pH levels
KF calibration refers to calibrating a Karl Fischer titrator to accurately measure water content
Each calibration requires specific standards and procedures
Regular calibration is necessary to maintain accurate measurements
Some of the top questions asked at the Reliance Life Sciences Senior Executive interview -
based on 1 interview
Interview experience
based on 30 reviews
Rating in categories
Executive
226
salaries
| ₹2.8 L/yr - ₹8 L/yr |
Deputy Manager
167
salaries
| ₹4.9 L/yr - ₹14.1 L/yr |
Senior Executive
149
salaries
| ₹2.5 L/yr - ₹11.5 L/yr |
Executive Production
113
salaries
| ₹2.4 L/yr - ₹6 L/yr |
Research Fellow
44
salaries
| ₹2.5 L/yr - ₹8.8 L/yr |
IQVIA
Syngene International
Aragen Life Sciences
SAI Life Sciences