Filter interviews by
Clear (1)
I applied via Campus Placement and was interviewed before May 2023. There was 1 interview round.
Top trending discussions
I was interviewed before Mar 2024.
Topics regarding the introduction or changes in the tax regime.
My strengths include attention to detail, strong analytical skills, and ability to work under pressure. My weaknesses include being overly critical of my own work and sometimes struggling with delegation.
Strengths: attention to detail
Strengths: strong analytical skills
Strengths: ability to work under pressure
Weaknesses: overly critical of my own work
Weaknesses: struggle with delegation
Operation and maintenance procedures are essential for ensuring the smooth functioning of equipment and systems.
Regular inspections and maintenance checks should be conducted to identify and address any issues before they become major problems.
Procedures should be documented and followed consistently to ensure safety and efficiency.
Training should be provided to all personnel involved in the operation and maintenance o...
I applied via Recruitment Consultant and was interviewed in Dec 2021. There was 1 interview round.
Transformers are rated in KVA because it represents the apparent power they can handle.
KVA stands for kilovolt-ampere, which is a unit of apparent power.
Transformers are designed to handle a certain amount of power, and the KVA rating indicates their capacity.
The KVA rating takes into account both the voltage and current that the transformer can handle.
It helps in determining the appropriate size and capacity of the tr...
The ground clearance of a 400KV transmission line varies depending on various factors.
The ground clearance of a transmission line is the vertical distance between the lowest point of the conductor and the ground.
The ground clearance is determined based on safety regulations and requirements.
Factors that influence the ground clearance include terrain, vegetation, and proximity to buildings or roads.
In hilly areas, the g...
The tan Delta value of electrical equipment should be as low as possible.
Tan Delta is a measure of the dielectric losses in electrical equipment.
A low tan Delta value indicates that the equipment has good insulation properties.
The tan Delta value can be affected by factors such as temperature, moisture, and aging of the equipment.
For transformers, a typical tan Delta value is around 0.001 or lower.
ACSRinvar conductors are widely used in metro principal cities due to their high strength and low thermal expansion.
ACSRinvar conductors have a high tensile strength, making them suitable for long-distance transmission lines in metro cities.
They have a low coefficient of thermal expansion, which helps in reducing sagging of the conductors and maintaining power transmission efficiency.
The use of ACSRinvar conductors in ...
The Basis setting of REF protection for a transformer should be determined based on the transformer's characteristics and the system requirements.
The basis setting of REF (Restricted Earth Fault) protection for a transformer is typically determined by considering the transformer's winding configuration, impedance, and the system's fault level.
The setting should be chosen to ensure that the protection operates reliably ...
The SF6 gas used for Ckt breaker chamber should be maintained at a pressure of around 5-7 bar.
The SF6 gas in the circuit breaker chamber should be maintained at a specific pressure to ensure proper functioning.
The recommended pressure for SF6 gas in the circuit breaker chamber is typically between 5 and 7 bar.
Maintaining the correct pressure helps in extinguishing the arc during circuit interruption.
Too low or too high...
Star-star zero phase shift transformer windings are used to provide a balanced three-phase output with zero phase shift between primary and secondary voltages.
Star-star zero phase shift transformer windings are commonly used in power distribution systems.
They are used to supply power to three-phase loads such as motors, generators, and transformers.
The windings are designed in such a way that the voltages in the primar...
AIS and GIS substations differ in their construction and insulation methods.
AIS (Air Insulated Substation) uses air as the insulation medium, while GIS (Gas Insulated Substation) uses SF6 gas.
AIS substations require larger land areas compared to GIS substations.
GIS substations are more compact and can be installed in urban areas where space is limited.
AIS substations are more susceptible to environmental factors like p...
Vibration dampers are used with conductors to reduce the risk of fatigue failure and damage caused by wind-induced vibrations.
Vibration dampers absorb and dissipate the energy generated by wind-induced vibrations in conductors.
They help to reduce the risk of fatigue failure and damage to the conductor and associated hardware.
Vibration dampers are typically installed at regular intervals along the length of the conducto...
The main function of LA in a substation is to protect electrical equipment from lightning strikes.
LA stands for Lightning Arrester.
It is installed in substations to divert lightning strikes away from sensitive equipment.
LA provides a low-impedance path for lightning current to flow to the ground.
It helps in preventing damage to transformers, circuit breakers, and other electrical devices.
LA operates by ionizing the air...
posted on 3 Mar 2024
I applied via Approached by Company
Transformer works on the principle of electromagnetic induction to transfer electrical energy between two or more circuits.
Transformers have two coils of wire, known as primary and secondary coils.
When an alternating current flows through the primary coil, it creates a changing magnetic field.
This changing magnetic field induces a voltage in the secondary coil, transferring electrical energy.
Transformers are used to st...
posted on 14 May 2024
I was interviewed before Feb 2024.
Maths and reasoning , basic aptitude and personal information
The network architecture of my previous organization consisted of a centralized data center with multiple branch offices connected via MPLS.
Centralized data center with redundant core switches and firewalls
Branch offices connected via MPLS for secure communication
Implemented VLANs to segregate network traffic
Configured and maintained routers, switches, and firewalls
Monitored network performance and security incidents
STP stands for Spanning Tree Protocol, a network protocol that ensures a loop-free topology in Ethernet networks.
STP is used to prevent loops in Ethernet networks by blocking redundant paths.
It selects a single path for data transmission while blocking others to prevent network loops.
STP operates by exchanging messages between network switches to determine the most efficient path.
STP can be improved with enhancements l...
Wireless troubleshooting involves identifying and resolving issues with wireless networks.
Check for physical obstructions that may be blocking the signal
Verify that the wireless router is properly configured and functioning
Ensure that the correct network SSID and password are being used
Check for interference from other electronic devices
Update firmware and drivers for network devices
posted on 26 Jul 2022
posted on 4 Jul 2023
CBT at designated venue as fixed by PGCIL and will be mentioned in the admit card.
Various types of conductors include copper, aluminum, and steel.
Copper: highly conductive, commonly used in electrical wiring
Aluminum: lighter and cheaper than copper, used in power lines
Steel: used in overhead transmission lines for strength and durability
based on 1 interview
Interview experience
Network Engineer
309
salaries
| ₹0 L/yr - ₹0 L/yr |
Field Engineer
121
salaries
| ₹0 L/yr - ₹0 L/yr |
Graduate Engineer
87
salaries
| ₹0 L/yr - ₹0 L/yr |
Network Engineer L1
58
salaries
| ₹0 L/yr - ₹0 L/yr |
Marketing Executive
45
salaries
| ₹0 L/yr - ₹0 L/yr |
Power Grid Corporation of India
Bharat Sanchar Nigam
Oil And Natural Gas Corporation
NTPC