Filter interviews by
Answers to technical questions related to analyzer technician job.
Column working principle is based on separation of components based on their affinity towards stationary and mobile phases.
PM gas chromatography involves sampling and analysis of particulate matter in gas streams.
CEMS PM involves continuous monitoring of particulate matter emissions from industrial sources.
Zirconia O2 analyzer works on the principle of m...
Top trending discussions
I applied via Approached by Company and was interviewed in Jul 2024. There was 1 interview round.
The unit of resistance is ohm (Ω), named after German physicist Georg Simon Ohm.
The unit symbol for resistance is Ω
Resistance is measured using an ohmmeter
1 ohm is equal to 1 volt per ampere (V/A)
The unit of current is Ampere (A)
The unit of current is named after the French physicist Andre-Marie Ampere
1 Ampere is defined as the flow of 1 Coulomb of charge per second
Commonly used prefixes for current include milliampere (mA) and microampere (μA)
posted on 12 Sep 2024
To install a temperature transmitter, you need to properly mount the transmitter, connect the wiring, configure the settings, and test the transmitter.
Mount the temperature transmitter in a suitable location near the temperature source.
Connect the wiring according to the manufacturer's instructions, ensuring proper grounding.
Configure the settings such as range, output signal, and calibration using the transmitter's di...
posted on 30 Mar 2024
posted on 3 Jan 2024
I applied via Approached by Company and was interviewed in Dec 2023. There was 1 interview round.
posted on 29 Dec 2023
I applied via Company Website and was interviewed in Nov 2023. There were 2 interview rounds.
posted on 5 Jul 2024
posted on 25 Mar 2023
I applied via Job Fair and was interviewed in Feb 2023. There were 2 interview rounds.
Instrumentation equipment refers to devices used to measure, control, and monitor various parameters in industrial processes.
Instruments like pressure gauges, flow meters, and temperature sensors are commonly used in instrumentation.
Control valves and actuators are used to regulate the flow of fluids or gases.
Programmable Logic Controllers (PLCs) are used for automation and control of processes.
Analytical instruments l...
A PLC panel wiring diagram is a visual representation of the electrical connections and components in a programmable logic controller panel.
A PLC panel wiring diagram shows the layout and connections of various components such as power supplies, input/output modules, relays, and sensors.
It helps technicians understand how the electrical signals flow within the panel and how different devices are interconnected.
The diag...
A control valve is a device used to regulate the flow of fluid or gas in a process system.
Control valves are commonly used in industries such as oil and gas, chemical, and power plants.
They can be operated manually or automatically through an electrical or pneumatic signal.
Control valves consist of a valve body, actuator, and positioner.
They can control variables such as flow rate, pressure, temperature, and level.
Exam...
A transmitter is a device used in instrumentation to convert a physical measurement into an electrical signal.
Transmitters are commonly used in industries such as oil and gas, chemical, and power plants.
They are used to measure variables such as pressure, temperature, flow rate, level, and pH.
Transmitters typically consist of a sensing element, signal conditioning circuitry, and an output signal.
The sensing element det...
Flow meters are devices used to measure the flow rate of a fluid or gas.
Flow meters are commonly used in industries such as oil and gas, water treatment, and manufacturing.
They can measure flow rates in various units such as liters per minute, cubic meters per hour, or gallons per minute.
Different types of flow meters include electromagnetic, ultrasonic, turbine, and differential pressure flow meters.
Flow meters can be...
posted on 7 Mar 2022
I applied via Walk-in
One by one all member questions
To use a fire extinguisher, remember the acronym PASS: Pull, Aim, Squeeze, Sweep.
Pull the pin to break the seal
Aim the nozzle at the base of the fire
Squeeze the handle to release the extinguishing agent
Sweep the nozzle from side to side until the fire is out
To fix a bearing in soft, first remove the old bearing and clean the area. Then, apply adhesive and insert the new bearing.
Remove the old bearing carefully
Clean the area thoroughly
Apply adhesive to the new bearing
Insert the new bearing into the soft
Allow the adhesive to dry completely
1 inch is equal to 25.4 mm.
1 inch = 25.4 mm
This is a conversion question from inches to millimeters
The conversion factor is constant and widely used in engineering and manufacturing
based on 1 review
Rating in categories
Senior Electrical Technician
5
salaries
| ₹6 L/yr - ₹12 L/yr |
Instrumentation Technician
5
salaries
| ₹2.7 L/yr - ₹10.2 L/yr |
Senior Instrumentation Technician
5
salaries
| ₹2.9 L/yr - ₹9.4 L/yr |
Electrical Supervisor
4
salaries
| ₹5.4 L/yr - ₹18 L/yr |
Safety Officer
4
salaries
| ₹3 L/yr - ₹13.8 L/yr |
Reliance Industries
Bharat Petroleum
Indian Oil Corporation
Hindustan Petroleum