The internal parts of a centrifugal pump include impeller, casing, shaft, bearings, and seals.
Impeller is the rotating component that imparts energy to the fluid.
Casing is the stationary component that encloses the impeller and directs the flow of fluid.
Shaft connects the impeller to the motor and transmits power.
Bearings support the shaft and reduce friction.
Seals prevent leakage of fluid along the shaft.
Other interna...
Centrifugal pump alignment dial gauge is used to ensure proper alignment of the pump shaft and motor shaft.
Dial gauge helps in measuring the misalignment between the pump and motor shafts.
It ensures that the pump operates smoothly and efficiently.
Misalignment can cause vibration, noise, and premature wear and tear of the pump components.
Dial gauge readings are used to adjust the pump and motor positions for proper alig...
Safety in a plant refers to the measures taken to prevent accidents and injuries to workers and damage to equipment.
Safety protocols and procedures should be established and followed strictly
Workers should be trained on safety measures and provided with appropriate safety gear
Regular maintenance and inspection of equipment and machinery
Emergency response plans should be in place and practiced
Regular safety audits and a...
Cooling tower is used to remove heat from the water-cooled system and release it into the atmosphere.
It is used in industries to cool down the water used in various processes.
It works on the principle of evaporation.
It helps in conserving water by recycling it.
It is commonly used in power plants, chemical plants, and oil refineries.
The tower is designed to maximize the contact between air and water to facilitate heat t
The centrifugal external part is called impeller.
The impeller is the rotating component of a centrifugal pump.
It is responsible for transferring energy from the motor to the fluid being pumped.
Examples of centrifugal pumps that use impellers include water pumps, chemical pumps, and sewage pumps.
100000
I applied via Company Website and was interviewed in Dec 2020. There were 5 interview rounds.
I applied via Referral and was interviewed in Sep 2024. There was 1 interview round.
posted on 28 Dec 2023
I applied via Company Website and was interviewed in Nov 2023. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Apr 2022. There was 1 interview round.
To remove fitment work checking injector change in ITI Fitter
Identify the injector that needs to be changed
Remove the old injector carefully
Clean the area around the injector
Install the new injector properly
Check for any leaks or damages
Test the injector to ensure proper functioning
posted on 19 Feb 2022
I applied via Walk-in and was interviewed in Jan 2022. There were 3 interview rounds.
The internal parts of a centrifugal pump include impeller, casing, shaft, bearings, and seals.
Impeller is the rotating component that imparts energy to the fluid.
Casing is the stationary component that encloses the impeller and directs the flow of fluid.
Shaft connects the impeller to the motor and transmits power.
Bearings support the shaft and reduce friction.
Seals prevent leakage of fluid along the shaft.
Other interna...
Centrifugal pump alignment dial gauge is used to ensure proper alignment of the pump shaft and motor shaft.
Dial gauge helps in measuring the misalignment between the pump and motor shafts.
It ensures that the pump operates smoothly and efficiently.
Misalignment can cause vibration, noise, and premature wear and tear of the pump components.
Dial gauge readings are used to adjust the pump and motor positions for proper alig...
Safety in a plant refers to the measures taken to prevent accidents and injuries to workers and damage to equipment.
Safety protocols and procedures should be established and followed strictly
Workers should be trained on safety measures and provided with appropriate safety gear
Regular maintenance and inspection of equipment and machinery
Emergency response plans should be in place and practiced
Regular safety audits and a...
Cooling tower is used to remove heat from the water-cooled system and release it into the atmosphere.
It is used in industries to cool down the water used in various processes.
It works on the principle of evaporation.
It helps in conserving water by recycling it.
It is commonly used in power plants, chemical plants, and oil refineries.
The tower is designed to maximize the contact between air and water to facilitate heat t
The centrifugal external part is called impeller.
The impeller is the rotating component of a centrifugal pump.
It is responsible for transferring energy from the motor to the fluid being pumped.
Examples of centrifugal pumps that use impellers include water pumps, chemical pumps, and sewage pumps.
100000
I applied via Naukri.com
Interview experience
based on 1 review
Rating in categories
HR Assistant
4
salaries
| ₹1 L/yr - ₹3 L/yr |
Geophysicist
4
salaries
| ₹12 L/yr - ₹22 L/yr |
Manager/Sr Manager - Facility Management
3
salaries
| ₹8.3 L/yr - ₹20 L/yr |
Assistant Executive Engineer
3
salaries
| ₹17 L/yr - ₹23 L/yr |
Shift Engineer
3
salaries
| ₹2.7 L/yr - ₹2.7 L/yr |
Reliance Industries
TCS
Infosys
Bharat Petroleum