Q1. Boiler cold start-up and shutdown process & types of emergencies in your experience, specific energy consumption, efficiency of boiler, coal size, GCV, What is 5S? How it is implemented in your company explain...
read moreAnswering questions related to power plant engineering including boiler start-up and shutdown, emergencies, and 5S implementation.
Boiler cold start-up involves purging the furnace, lighting the burner, and gradually increasing the temperature and pressure.
Shutdown process involves cooling down the boiler, draining the water, and cleaning the furnace.
Types of emergencies include boiler tube leaks, fires, explosions, and power outages.
Specific energy consumption depends on the ...read more
Q2. What are safely precautions you used in while working on height
I always prioritize safety when working at heights by following specific precautions.
Wearing appropriate personal protective equipment (PPE) such as safety harnesses, helmets, and non-slip footwear
Using fall protection systems like guardrails, safety nets, or lifelines
Regularly inspecting and maintaining equipment like ladders, scaffolds, and platforms
Ensuring proper training and certification for working at heights
Implementing a buddy system or having a spotter to provide as...read more
Q3. Define 5S system ? what is the use of 5s ?
5S system is a workplace organization method that aims to improve efficiency and productivity by eliminating waste and optimizing workflow.
5S stands for Sort, Set in Order, Shine, Standardize, and Sustain
Sort involves removing unnecessary items from the workplace
Set in Order involves organizing the remaining items in a logical and efficient manner
Shine involves cleaning and maintaining the workplace
Standardize involves creating and implementing standard procedures for maintai...read more
Q4. What will you do during plant black out and island ?
During a plant black out and island, I would prioritize safety, assess the situation, implement emergency protocols, and work to restore power.
Prioritize safety of personnel and equipment
Assess the situation to determine the cause of the blackout
Implement emergency protocols to ensure stability of the plant
Work to restore power by troubleshooting and fixing the issue
Communicate with relevant stakeholders and authorities
Q5. What are the water parameters in feed water and steam path.
Water parameters in feed water and steam path are crucial for efficient operation and maintenance of the system.
Feed water parameters include pH level, conductivity, dissolved oxygen, and total dissolved solids.
Steam path parameters include steam pressure, temperature, and quality.
Maintaining proper water parameters is essential to prevent corrosion, scaling, and other issues in the system.
Regular monitoring and testing of water parameters is necessary to ensure optimal perfo...read more
Q6. Difference between severity and priority
Severity is the impact of a bug on the system, while priority is the urgency of fixing it.
Severity is the measure of how much a bug affects the system functionality.
Priority is the importance of fixing a bug based on business needs.
Example: A critical bug that crashes the system has high severity and high priority.
Example: A cosmetic bug that doesn't affect functionality has low severity but high priority if it's a customer-facing issue.
Q7. Sort Set Shine Standardize Sustain
Sort Set Shine Standardize Sustain are the 5S principles of workplace organization.
Sort: Remove unnecessary items from the workplace.
Set: Organize the remaining items in a logical manner.
Shine: Clean and maintain the workplace regularly.
Standardize: Establish procedures and standards for maintaining the workplace.
Sustain: Continuously improve and sustain the 5S principles.
Q8. Difference between Fe 415 and 500
Fe 415 and 500 are different grades of steel used in construction.
Fe 415 has a yield strength of 415 MPa, while Fe 500 has a yield strength of 500 MPa.
Fe 415 is commonly used for residential construction, while Fe 500 is used for commercial and industrial structures.
Fe 500 provides higher strength and durability compared to Fe 415.
Fe 415 is more economical than Fe 500.
Fe 415 is suitable for areas with low seismic activity, while Fe 500 is recommended for high seismic zones.
Q9. Mobile tools you used
I have experience using mobile tools such as Android Studio, Xcode, and React Native for app development.
Android Studio
Xcode
React Native
Q10. How provision is estimated. etc.
Provision is estimated based on past experience, current trends, and future expectations.
Provision is an estimate of a liability or expense that may occur in the future.
It is based on past experience, current trends, and future expectations.
Provision can be estimated for various expenses such as bad debts, warranties, and legal claims.
The estimation process involves analyzing historical data, market trends, and economic conditions.
Provision is important for financial reportin...read more
Q11. What is a AFBC Boiler?
AFBC Boiler stands for Atmospheric Fluidized Bed Combustion Boiler, which is a type of boiler that utilizes a bed of hot particles to burn fuel.
Utilizes a bed of hot particles to burn fuel
Operates at atmospheric pressure
Suitable for fuels with low quality and high ash content
Q12. Describe boiler cold start up procedure.
Boiler cold start up procedure involves several steps to ensure safe and efficient operation.
Check water level in the boiler to ensure it is at the correct level
Open the main steam valve and close the bypass valve
Start the boiler feed water pump to fill the boiler with water
Purge the air from the boiler by opening the air vent valves
Turn on the boiler burner and ignite the fuel to start heating the water
Monitor the boiler pressure and temperature to ensure they are within saf...read more
Q13. Types of transformers
Transformers are devices that transfer electrical energy between two or more circuits through electromagnetic induction.
Step-up transformer increases voltage levels (e.g. power distribution)
Step-down transformer decreases voltage levels (e.g. household appliances)
Auto transformer has a single winding with multiple taps for voltage adjustment
Isolation transformer provides electrical isolation between input and output circuits
Distribution transformer used in power distribution ...read more
Q14. Types of motors and turbines
Types of motors include AC motors, DC motors, synchronous motors, and induction motors. Turbines include steam turbines, gas turbines, and wind turbines.
AC motors: commonly used in household appliances and industrial applications
DC motors: used in electric vehicles, robotics, and small household appliances
Synchronous motors: used in applications requiring precise speed control
Induction motors: widely used in industrial settings for their reliability and efficiency
Steam turbin...read more