I applied via Walk-in and was interviewed before Oct 2022. There was 1 interview round.
Assignment is given related to my previous experience that water system qualifications and HVAC maintenance
posted on 24 Dec 2023
I applied via Approached by Company and was interviewed in Nov 2023. There were 2 interview rounds.
Star delta starter is used in induction motors to reduce starting current and torque.
Reduces starting current by starting the motor in star connection and then switching to delta connection
Reduces starting torque to prevent mechanical stress on the motor and connected equipment
Suitable for applications where high starting current and torque are not required, such as fans, pumps, and compressors
This can be achieved by changing the phase sequence of the motor.
Motor direction can be changed by swapping any two of the three-phase wires.
This will change the phase sequence and hence the direction of rotation.
For example, swapping wires A and B in a three-phase motor will change the direction of rotation.
PLC stands for Programmable Logic Controller.
PLC is a digital computer used for automation of electromechanical processes.
It is commonly used in industries to control machinery and processes.
PLCs are programmed using specialized software to perform specific tasks.
Examples of PLC brands include Siemens, Allen-Bradley, and Mitsubishi.
An automatically plant is a facility where various processes are controlled and operated automatically without the need for constant human intervention.
Automatically controlled processes
Utilizes sensors and programmable logic controllers (PLCs)
Reduces the need for manual labor
Examples: automated assembly lines, robotic manufacturing plants
I applied via Company Website and was interviewed in Oct 2023. There was 1 interview round.
I applied via LinkedIn and was interviewed in Sep 2022. There was 1 interview round.
My name is [insert name here].
My name is [insert name here].
I prefer to go by [insert preferred name here].
I was born and raised in [insert place of origin here].
I have [insert number of years] of experience in [insert relevant field here].
I applied via Naukri.com and was interviewed in Jan 2021. There was 1 interview round.
I was interviewed in Aug 2017.
Calibration is the process of adjusting or verifying the accuracy of a measuring instrument or device.
Calibration ensures that measurements taken by an instrument are accurate and reliable.
It involves comparing the measurements of a device to a known standard.
Calibration may involve adjusting the device to bring it in line with the standard.
It is important in various fields like engineering, manufacturing, and scientif...
Calibrating temperature indicators involves adjusting them to ensure accurate readings.
Calibration of temperature indicators involves comparing their readings to a known standard.
Adjustments are made to the indicators to align their readings with the standard.
Calibration may involve adjusting the zero point and span of the indicators.
Examples of temperature indicators include thermometers, temperature sensors, and temp
Calibration of RTDs involves comparing the sensor's output to a known reference and adjusting it accordingly.
RTDs (Resistance Temperature Detectors) are calibrated to ensure accurate temperature measurements.
Calibration involves comparing the RTD's resistance values at different temperatures to a known reference.
Adjustments are made to the RTD's output signal to align it with the reference values.
Calibration can be don...
There are several types of flow meters used in various industries to measure the flow rate of fluids or gases.
Some common types of flow meters include electromagnetic flow meters, ultrasonic flow meters, turbine flow meters, and positive displacement flow meters.
Electromagnetic flow meters use Faraday's law of electromagnetic induction to measure the flow rate of conductive fluids.
Ultrasonic flow meters utilize ultraso...
To check door interlock systems, inspect the physical components, test the electrical connections, and verify proper functioning.
Inspect the door hinges, latches, and locks for any damage or misalignment.
Check the wiring connections and ensure they are secure and not damaged.
Test the interlock switch by opening and closing the door to see if it activates properly.
Verify that the interlock system prevents the door from ...
To calibrate pressure gauges, vacuum gauges, and compound gauges, follow these steps:
Use a known reference pressure source to compare the readings of the gauges.
Adjust the gauges if there is any deviation from the reference pressure.
Repeat the process multiple times to ensure accuracy.
Document the calibration process and results for future reference.
Perform regular calibrations to maintain accuracy.
Example: For pressur...
I applied via Walk-in and was interviewed before Oct 2022. There was 1 interview round.
based on 3 interviews
Interview experience
based on 2 reviews
Rating in categories
Officer
196
salaries
| ₹2 L/yr - ₹5.5 L/yr |
Senior Officer
192
salaries
| ₹2.9 L/yr - ₹6.8 L/yr |
Assistant Officer
145
salaries
| ₹1.7 L/yr - ₹3.5 L/yr |
Research Associate
113
salaries
| ₹1.9 L/yr - ₹5.3 L/yr |
Production Officer
87
salaries
| ₹2.3 L/yr - ₹4.8 L/yr |
Aarti Industries
Vinati Organics
Atul
Navin Fluorine International