Epitome Components
R Systems International Interview Questions and Answers
Q1. In 3 phase 1 phase not work what are u do to protect motor
Use a phase failure relay to protect the motor.
Install a phase failure relay to detect the absence of a phase and disconnect the motor from the supply.
Check the motor's wiring and connections to ensure they are correct and secure.
If the motor is already running, shut it down immediately to prevent damage.
Consult with an electrician to determine the cause of the phase failure and resolve the issue.
Consider using a backup power source or generator to prevent future phase failur...read more
Q2. What is Ohms Law & Describe Current Voltage relationship
Ohm's Law states that the current flowing through a conductor is directly proportional to the voltage applied across it, given a constant resistance.
Ohm's Law: V = I * R (Voltage = Current * Resistance)
Current is directly proportional to Voltage when Resistance is constant
Higher voltage leads to higher current flow, and vice versa
Lower resistance leads to higher current flow, and vice versa
Example: If a circuit has a voltage of 12V and a resistance of 4 ohms, the current flow...read more
Q3. What is compressor and it's unit
A compressor is a mechanical device that increases the pressure of a gas by reducing its volume.
Compressors are used in various industries such as refrigeration, air conditioning, and gas processing.
They come in different types such as reciprocating, rotary, and centrifugal compressors.
The unit of a compressor is typically measured in cubic feet per minute (CFM) or liters per minute (LPM).
Q4. What is No,Nc
No, NC stands for Normally Open and Normally Closed.
No, NC are terms used in electrical circuits.
No refers to Normally Open, which means the circuit is open when there is no current flowing through it.
NC refers to Normally Closed, which means the circuit is closed when there is no current flowing through it.
These terms are commonly used in relays, switches, and other electrical components.
Understanding No, NC is important for troubleshooting and maintenance of electrical syst...read more
Q5. What is Star Delta Starter Diagram
Star Delta Starter Diagram is a method used to reduce the starting current of induction motors.
Consists of three contactors - one for star connection and two for delta connection
Switches from star to delta configuration after motor reaches a certain speed
Reduces starting current by starting in star configuration and then switching to delta
Q6. What is Types of Motors
Types of motors include AC motors, DC motors, synchronous motors, asynchronous motors, and stepper motors.
AC motors: Alternating current motors commonly used in household appliances and industrial applications.
DC motors: Direct current motors used in applications where speed control is important, such as in robotics.
Synchronous motors: Motors that rotate at a fixed speed determined by the frequency of the applied voltage.
Asynchronous motors: Motors that rotate at a speed slig...read more
Q7. what Is KCL and KVL
KCL stands for Kirchhoff's Current Law and KVL stands for Kirchhoff's Voltage Law.
KCL states that the total current entering a junction is equal to the total current leaving the junction.
KVL states that the sum of voltage drops around a closed loop in a circuit is equal to the sum of voltage sources in that loop.
These laws are fundamental principles in circuit analysis and are used to solve complex electrical circuits.