UPLC stands for Ultra Performance Liquid Chromatography.
UPLC is a technique used in analytical chemistry to separate, identify, and quantify components in a mixture.
It is an advanced form of liquid chromatography that utilizes smaller particle sizes and higher pressures for faster and more efficient separations.
UPLC is commonly used in pharmaceutical, environmental, and food analysis.
It offers improved resolution, sens...
I applied via Company Website and was interviewed before Dec 2020. There were 3 interview rounds.
I applied via Referral and was interviewed in Jun 2021. There were 5 interview rounds.
Basic quant Questions
Validation ensures that the system meets the user's needs, while qualification ensures that the system is installed and operates correctly.
Validation confirms that the system meets the user's requirements and expectations.
Qualification ensures that the system is installed correctly and operates within predefined specifications.
Validation is more focused on user needs and expectations, while qualification is more focuse...
GLP stands for Good Laboratory Practice, which ensures the reliability and integrity of data generated in a laboratory setting.
GLP is a set of guidelines for conducting non-clinical safety studies on chemicals, pharmaceuticals, and other products.
It includes requirements for the organization, personnel, facilities, equipment, and documentation of studies.
Data integrity refers to the accuracy, completeness, and reliabil...
HPLC and GC are analytical techniques used in chemistry to separate and analyze compounds in a mixture.
HPLC stands for High Performance Liquid Chromatography, which uses a liquid mobile phase to separate compounds based on their interactions with a stationary phase.
GC stands for Gas Chromatography, which uses a gas mobile phase to separate compounds based on their volatility and interactions with a stationary phase.
Bot...
Tableau Developer
I was given an assignment where I had to build dashboard with final story within 1 hour
I applied via Walk-in and was interviewed in Aug 2023. There were 2 interview rounds.
UV, IR, KF, and polarimeter are analytical instruments used for different types of analysis based on principles of light absorption, emission, and rotation.
UV (Ultraviolet) spectrophotometer measures the absorption of ultraviolet light by a sample to determine its concentration or purity.
IR (Infrared) spectrophotometer measures the absorption of infrared light by a sample to identify functional groups in organic compou...
Calibration of analytical balance is essential for accurate measurements in analytical chemistry.
Calibration involves comparing the readings of the balance to known weights.
Regular calibration ensures accuracy and reliability of measurements.
Adjustments may be needed if the balance readings deviate from the known weights.
Calibration should be done using a proper calibration weight and following manufacturer's instructi...
PH range is 0-14. Calibration ensures accuracy by adjusting the PH meter to known standards.
PH range is from 0 to 14, with 7 being neutral
Acidic solutions have a PH below 7, while alkaline solutions have a PH above 7
Calibration involves adjusting the PH meter using buffer solutions of known PH values
Regular calibration ensures accurate PH measurements
based on 1 interview
Interview experience
Senior Associate Manager
228
salaries
| ₹9 L/yr - ₹30.1 L/yr |
Associate Consultant
171
salaries
| ₹10.7 L/yr - ₹25.7 L/yr |
Associate Manager
163
salaries
| ₹8.1 L/yr - ₹21.5 L/yr |
Consultant
115
salaries
| ₹21 L/yr - ₹41 L/yr |
Senior Associate Consultant
111
salaries
| ₹15.4 L/yr - ₹34 L/yr |
Hetero
Viatris
Abbott
Akums Drugs & Pharmaceuticals Limited