A 132kV switch yard single line drawing shows the layout of electrical components and connections in a high voltage switch yard.
Include details of the incoming and outgoing lines connected to the switch yard
Show the location of circuit breakers, isolators, transformers, and other equipment
Indicate the protection and control systems used in the switch yard
Include any busbars, disconnectors, and surge arresters in the la
Generator protection schemes are designed to prevent damage to the generator and ensure safe operation.
Differential protection: compares currents at both ends of the generator winding to detect internal faults
Overcurrent protection: trips the generator if current exceeds a certain threshold
Loss of excitation protection: detects loss of excitation voltage and trips the generator to prevent damage
Reverse power protection...
Top trending discussions
I applied via Whatsapp and was interviewed in May 2024. There were 2 interview rounds.
The minimum megger value of a good motor is typically 1 megohm or higher.
A good motor should have a megger value of at least 1 megohm to ensure proper insulation resistance.
Lower megger values may indicate insulation issues or potential breakdowns in the motor.
Regular megger testing is important to detect any insulation problems in motors.
For high voltage motors, the minimum megger value may be higher than 1 megohm.
The kVA transformer installed in the plant is 500 kVA.
The kVA transformer installed in the plant is 500 kVA.
The kVA rating of the transformer is crucial for determining the power capacity of the plant.
It is important to regularly check and maintain the transformer to ensure optimal performance.
The kVA rating indicates the maximum load that the transformer can handle without overheating.
posted on 4 Feb 2024
I was interviewed before Feb 2023.
I was interviewed in Sep 2023.
posted on 8 May 2022
I applied via Referral and was interviewed in Nov 2021. There were 4 interview rounds.
Self thinking releated
posted on 17 Nov 2019
I applied via Company Website and was interviewed in Nov 2019. There were 4 interview rounds.
The maximum voltage of transmission line in India is 765 kV.
The highest voltage level in India is 765 kV.
This voltage level is used for long distance transmission of electricity.
India has several high voltage transmission lines, including the Raigarh-Pugalur HVDC line.
The maximum voltage level has increased over the years, from 400 kV to 765 kV.
Higher voltage levels allow for more efficient transmission of electricity.
Various methods like V/F control, rotor resistance control, and vector control are used for speed control of induction motors.
V/F control method varies the frequency and voltage supplied to the motor to control its speed.
Rotor resistance control method involves inserting external resistance in the rotor circuit to control the speed.
Vector control method uses advanced algorithms to control the speed and torque of the mo...
Interview experience
Assistant Manager
57
salaries
| ₹6 L/yr - ₹12.6 L/yr |
Officer
26
salaries
| ₹3.3 L/yr - ₹7 L/yr |
Assistant Process Incharge
24
salaries
| ₹2.8 L/yr - ₹5 L/yr |
Senior Officer
23
salaries
| ₹4.8 L/yr - ₹9 L/yr |
Deputy Manager
22
salaries
| ₹8 L/yr - ₹15 L/yr |
ITC
Bilt
Tamilnadu Newsprint Papers
JK Paper