i
Acme Generics LLP
Filter interviews by
Peak purity is a measure of the homogeneity of a chromatographic peak, indicating the presence of impurities or co-eluting compounds.
Peak purity is determined by comparing the spectra of the peak at different wavelengths.
A pure peak will have a consistent spectrum across different wavelengths, while impurities will show variations.
Peak purity analysis is commonly used in pharmaceutical and analytical chemistry to ensur...
Noise is unwanted or unpleasant sound that can cause disturbance or harm to human health.
Noise can be caused by various sources such as traffic, construction, industrial machinery, and loud music.
Exposure to high levels of noise can lead to hearing loss, stress, and other health problems.
Noise pollution is a growing concern in urban areas and can have negative impacts on both humans and wildlife.
Noise can be measured i...
About refers to an approximate amount or quantity.
About means approximately or roughly.
It is used when an exact amount is not known or specified.
For example, 'I need about 2 cups of flour for this recipe.'
Temperature affects the separation and retention time of analytes in HPLC analysis.
Higher temperature can decrease retention time and resolution.
Lower temperature can increase retention time and resolution.
Temperature should be controlled and kept constant during analysis.
Column temperature can affect the selectivity of the stationary phase.
Temperature can also affect the viscosity of the mobile phase and the solubilit
LOQ and LOD values are used in analytical chemistry to determine the lowest concentration of a substance that can be reliably detected and quantified.
LOQ stands for Limit of Quantification and is the lowest concentration of a substance that can be reliably quantified.
LOD stands for Limit of Detection and is the lowest concentration of a substance that can be reliably detected.
LOD is usually higher than LOQ.
LOQ and LOD ...
Top trending discussions
I applied via Walk-in and was interviewed in Jun 2023. There were 5 interview rounds.
Equipment installation and qualification involves a detailed process to ensure proper functioning and compliance.
Start by planning the installation process, including site preparation and equipment layout.
Follow manufacturer's instructions for installation, including electrical connections and plumbing.
Perform equipment qualification tests to verify performance and functionality.
Document all installation and qualificat...
I applied via Referral and was interviewed before May 2023. There were 3 interview rounds.
I applied via Approached by Company and was interviewed before Dec 2023. There was 1 interview round.
Membrane filtration method is commonly used for the analysis of Total Aerobic Microbial Count (TAMC) in water.
Membrane filtration method is commonly used for TAMC analysis in water
Other methods include pour plate method and spread plate method
Membrane filters are used to trap and grow bacteria colonies for counting
Results are expressed as colony forming units per milliliter (CFU/mL)
The limit of water BET refers to the maximum amount of water that can be adsorbed onto a material's surface using the BET method.
The limit of water BET is typically around 40-50% relative humidity.
It is important to consider the specific surface area and pore size distribution of the material when determining the water BET limit.
For example, materials with larger surface areas and smaller pore sizes may have higher wat...
I applied via Walk-in and was interviewed in May 2022. There was 1 interview round.
Deviation is the amount by which a single measurement differs from a fixed value or average.
Deviation is a measure of how spread out the values in a data set are.
It is calculated by finding the difference between each data point and the mean of the data set.
Positive deviations indicate values above the mean, while negative deviations indicate values below the mean.
Deviation is commonly used in statistics to analyze the
There are two main types of deviations: positive deviations and negative deviations.
Positive deviations occur when actual results exceed expected results.
Negative deviations occur when actual results fall short of expected results.
Qualifying a washing and depyrogenation tunnel involves testing and validating its performance to ensure it meets regulatory requirements.
Performing validation tests to ensure the tunnel effectively removes contaminants and pyrogens
Conducting temperature mapping studies to verify uniformity throughout the tunnel
Testing the sterilization process to ensure it meets specified parameters
Documenting all validation activitie...
posted on 24 Jun 2023
I applied via Recruitment Consulltant and was interviewed in Jul 2022. There were 2 interview rounds.
I applied via Approached by Company and was interviewed before Jan 2022. There were 3 interview rounds.
To know about your basic skill, talking style, confidence, leadership etc.
posted on 5 Sep 2021
based on 14 reviews
Rating in categories
Senior Officer
137
salaries
| ₹2.7 L/yr - ₹5.2 L/yr |
Officer
97
salaries
| ₹1.8 L/yr - ₹3.8 L/yr |
Executive
61
salaries
| ₹4 L/yr - ₹6.4 L/yr |
Senior Executive
46
salaries
| ₹5 L/yr - ₹7.6 L/yr |
Assistant Manager
22
salaries
| ₹6.6 L/yr - ₹11 L/yr |
Sun Pharmaceutical Industries
Cipla
DRJ & CO
Lupin