Aarti Industries
Kothari Distributors Interview Questions and Answers
Q1. Tell me about parameters you observed in clean room area.
In a clean room area, parameters observed include air quality, temperature, humidity, particle count, and pressure differentials.
Air quality is monitored to ensure low levels of contaminants.
Temperature is controlled to maintain a stable environment for sensitive equipment.
Humidity levels are regulated to prevent moisture-related issues.
Particle count is measured to ensure cleanliness and prevent contamination.
Pressure differentials are maintained to prevent the entry of outs...read more
Q2. If i opened centrifugal pump tell?
When opening a centrifugal pump, it is important to follow proper procedures to ensure safety and prevent damage.
Before opening the pump, ensure that it is isolated from the power source and all pressure has been relieved.
Inspect the pump for any signs of damage or wear, such as leaks, cracks, or excessive vibration.
Check the pump's impeller and casing for any debris or blockages that may affect its performance.
If necessary, remove the pump's cover or casing using appropriate...read more
Q3. How the vacuum created in steam ejector?
Vacuum is created in a steam ejector through the principle of jet propulsion.
Steam ejectors use high-pressure steam to create a low-pressure environment.
The steam enters the nozzle of the ejector and expands, creating a high-velocity jet.
This high-velocity jet entrains and compresses the surrounding gas or vapor, reducing its pressure.
The entrained gas or vapor is then discharged through the diffuser, creating a vacuum.
The vacuum created by the steam ejector is used for vario...read more
Q4. What equipments are you handled?
I have handled a wide range of equipment in my role as a Mechanical Maintenance Engineer.
Pumps and compressors
Conveyors and material handling equipment
Boilers and heat exchangers
HVAC systems
Generators and power distribution systems
Machine tools and production equipment
Hydraulic and pneumatic systems
Crane and lifting equipment
Instrumentation and control systems
Q5. Tell me mechanical seal types.
Mechanical seal types include cartridge seals, component seals, and bellows seals.
Cartridge seals are pre-assembled units that are easy to install and replace.
Component seals are made up of separate rotating and stationary parts.
Bellows seals use a flexible metal bellows to provide a dynamic seal.
Q6. 1 torr=? Mmof hg
1 torr is equal to 0.03937 mm of Hg.
1 torr is a unit of pressure equal to 1/760th of standard atmospheric pressure.
mm of Hg is a unit of pressure commonly used in vacuum systems.
To convert torr to mm of Hg, multiply by 0.03937.
Example: 1 torr = 1 * 0.03937 mm of Hg = 0.03937 mm of Hg.
Q7. 759 mm of hg
759 mm of hg is a unit of pressure measurement.
mm of hg is a common unit used to measure pressure.
759 mm of hg is equivalent to 1012.8 millibars or 14.1 pounds per square inch (psi).
It is often used in meteorology to measure atmospheric pressure.
In mechanical maintenance, it can be used to monitor pressure in systems or equipment.
For example, if a pressure gauge reads 759 mm of hg, it indicates the pressure exerted by a fluid in a system.
Top HR Questions asked in Kothari Distributors
Interview Process at Kothari Distributors
Top Mechanical Maintenance Engineer Interview Questions from Similar Companies
Reviews
Interviews
Salaries
Users/Month