Q1. Control valve internal leakages how is check
Control valve internal leakages can be checked through various methods.
Performing a visual inspection of the valve and its components
Using ultrasonic leak detection equipment
Conducting a pressure drop test
Performing a bubble test using a soap solution
Checking the valve position indicator
Analyzing the valve's performance data
Regular maintenance and testing of the valve
Q2. Explain the series and parallel connections
Series and parallel connections are two types of electrical circuits used to connect components.
In a series connection, components are connected end-to-end, so the current flows through each component in turn.
In a parallel connection, components are connected side-by-side, so the current is divided among them.
Series connections increase the total resistance and decrease the total current, while parallel connections decrease the total resistance and increase the total current....read more
Q3. Breaking failure how is solved
Breaking failure can be solved by identifying the root cause and implementing corrective actions.
Identify the root cause of the breaking failure
Implement corrective actions such as repairing or replacing the broken parts
Conduct regular maintenance and inspections to prevent future breaking failures
Train employees on proper usage and maintenance of equipment
Use high-quality materials and equipment to reduce the risk of breaking failures
Q4. Different between pump and motor
Pump is used to transfer fluids while motor is used to convert electrical energy into mechanical energy.
Pump is used to move fluids from one place to another while motor is used to rotate machinery.
Pump has an inlet and outlet while motor has a rotor and stator.
Pump is used in fluid systems while motor is used in mechanical systems.
Examples of pumps include centrifugal pumps, positive displacement pumps, and axial flow pumps. Examples of motors include AC motors, DC motors, a...read more
Q5. Hydraulic cylinder operation slow
Possible causes of slow hydraulic cylinder operation
Low hydraulic fluid level
Clogged or dirty hydraulic filter
Worn out piston seals
Leaking hydraulic lines
Faulty control valve
Incorrectly adjusted relief valve
Excessive load on the cylinder
Improperly sized cylinder for the application
Q6. Explain the fuel system
The fuel system is responsible for delivering fuel to the engine for combustion.
The fuel system includes the fuel tank, fuel pump, fuel filter, fuel injectors, and carburetor.
The fuel pump draws fuel from the tank and sends it to the engine.
The fuel filter removes impurities from the fuel before it reaches the engine.
Fuel injectors spray fuel into the engine's combustion chamber, while a carburetor mixes fuel and air before sending it to the engine.
The fuel system must be reg...read more