PQC:- total thickness 300mm use M40 grade concrete, aggregate size 31.5mm. Textue strength of cement concete 4.5 Mpa., compressive strength concrete after 28 days curing 40Mpa. Expension joint provided dowel bar load transfer to one slab to another slab. Expension joint thicknesses 25mm water and dirt enter the joint dowel bar effect to corrosion.,and expected stress on the joint and resulting restrained movement.PVC dowel sheet size 34mm×100micron dowel bar 32mm dia 500mm length plain bar.330mm dowe bar full of greasing and pvc dowel sheet inserting. 130mm dowel bar epxy coated.

AnswerBot
1y

The question pertains to the expected stress and restrained movement on an expansion joint with dowel bar load transfer.

  • Total thickness of 300mm with M40 grade concrete and 31.5mm aggregate size.

  • Textu...read more