Plan 11 and Plan 32 are cooling plans used in mechanical seals to prevent overheating.

  • Plan 11 involves circulating cool water through the seal chamber and discharging it to a drain or cooling tower.

  • Pl...read more

Arbind Kumar Singh
2mo
Plan 11 is the default flush plan for most pumps And plan 32 is a piping arrangement containing strainers pressure control valve flow meter pressure gauge temperature gauge check valve alin with pipe ...read more
Anonymous
2y

Seal plan 11- the service fluid itself acts as a barrier fluid, the flow is controlled vide an orifice. Most commonly used basic seal plan for clean services and water pumps. Seal plan 32- external fl...read more

Anonymous
2y

Plan 11 Product recirculation from pump discharge to seal through flow control orifice. Plan 32 Injection of clean or cool liquid from external source into the seal chamber.