i
dsm-firmenich
Filter interviews by
I applied via LinkedIn and was interviewed in Jan 2022. There were 2 interview rounds.
Reflux is used in distillation column for temperature and purity maintenance in product.
Reflux helps in maintaining a constant temperature in the distillation column.
It also helps in achieving a higher purity of the product by preventing the vaporized product from escaping the column.
Reflux is achieved by condensing some of the vaporized product and returning it back to the column.
This process helps in achieving a more...
Safety in IBC in charge in reactor involves various measures such as IBC in property arthing plate, vent, interlock, PPE, etc.
IBC in property arthing plate is used to prevent static electricity buildup and discharge.
Ventilation systems are installed to ensure proper air circulation and prevent the accumulation of hazardous gases.
Interlock systems are implemented to ensure safe operation and prevent unauthorized access.
...
Increase vacuum and temperature to recover any remaining chemical.
Increase vacuum to lower the boiling point of the chemical.
Raise temperature to increase the vapor pressure of the chemical.
Use a condenser to collect the vapor and recover the chemical.
Repeat the process until no more chemical can be recovered.
Dispose of any remaining waste safely and responsibly.
DCS stands for Distributed Control System and includes open loop, closed loop, and cascade loop control strategies.
DCS is a computerized control system used to manage and automate industrial processes.
Open loop control is a control strategy where the output is not measured or compared to the input.
Closed loop control is a control strategy where the output is measured and compared to the input to adjust the process.
Casc...
Top trending discussions
Document handling during AUDIT process
During AUDIT process, all relevant documents must be handled with utmost care
Documents must be organized and easily accessible for auditors
Any missing or incomplete documents must be identified and addressed
Proper documentation of the audit process is crucial for future reference
Expected job profile includes managing production processes and ensuring timely delivery. Expected facility should have necessary equipment and resources.
Job profile involves overseeing production processes and ensuring quality standards are met
Responsible for managing production schedules and ensuring timely delivery of products
Expected facility should have necessary equipment and resources to support production proce...
I was interviewed in Nov 2020.
posted on 22 Nov 2024
posted on 23 Mar 2024
I applied via LinkedIn and was interviewed in Sep 2023. There was 1 interview round.
The help of the resin packed in a column can be found using the formula: H = L / (1 - ε)
Calculate the height of the resin packed in a column using the formula H = L / (1 - ε)
H is the height of the resin packed in the column
L is the length of the column
ε is the void fraction of the resin bed
The formula helps in determining the effective height of the resin bed in the column
I applied via Approached by Company and was interviewed in Sep 2023. There were 2 interview rounds.
posted on 26 Apr 2023
posted on 1 Aug 2023
I applied via Indeed and was interviewed before Aug 2022. There were 2 interview rounds.
DMAIC is a data-driven improvement cycle used in Six Sigma methodology to optimize processes.
Define: Identify the problem and set project goals.
Measure: Collect data to understand current process performance.
Analyze: Identify root causes of issues and develop solutions.
Improve: Implement and test solutions to improve the process.
Control: Establish controls to sustain improvements over time.
Example: Using DMAIC to reduc...
I applied via Company Website and was interviewed in Oct 2021. There was 1 interview round.
I applied via Walk-in and was interviewed in Mar 2024. There were 2 interview rounds.
Laminar airflow is a smooth, uninterrupted flow of air in a consistent direction.
Laminar airflow moves in parallel layers with minimal turbulence
It is typically achieved through the use of HEPA filters in cleanrooms and operating theaters
Laminar airflow helps to reduce the risk of contamination in controlled environments
Some of the top questions asked at the dsm-firmenich Production interview -
based on 1 review
Rating in categories
Senior Executive
16
salaries
| ₹9.8 L/yr - ₹17.5 L/yr |
Executive
13
salaries
| ₹9.3 L/yr - ₹14 L/yr |
Accounts Manager
12
salaries
| ₹19 L/yr - ₹36.5 L/yr |
Production Operator
12
salaries
| ₹4.8 L/yr - ₹12.5 L/yr |
Senior Manager
11
salaries
| ₹26 L/yr - ₹50 L/yr |
Symrise
Givaudan
International Flavors & Fragrances
Takasago International India