Q1. What kind of metals in indoor unit and outdoor unit coil

Ans.

The indoor unit and outdoor unit coils are typically made of metals such as copper, aluminum, or a combination of both.

  • Common metals used in coils are copper and aluminum

  • Some coils may be made of a combination of copper and aluminum for better heat transfer

  • Other metals like steel may also be used in some cases

View 1 answer

Q2. Why the copper pipe between indoor unit and outdoor unit is covered by foam and white roll

Ans.

The copper pipe between indoor and outdoor units is covered by foam and white roll for insulation and protection against external elements.

  • The foam provides insulation to prevent heat loss or gain during the refrigerant transfer process

  • The white roll acts as a protective layer to shield the copper pipe from external damage such as UV rays, moisture, and physical impact

  • The insulation and protection help maintain the efficiency and longevity of the HVAC system

View 1 answer

Q3. Why we loosing the flare nut in union is kept by two adjustable spanner

Ans.

Using two adjustable spanners to tighten a flare nut in a union can lead to it loosening due to uneven pressure distribution.

  • Using two adjustable spanners can result in uneven pressure being applied to the flare nut

  • This can cause the flare nut to become loose over time

  • It is recommended to use a proper flare nut wrench for tightening flare nuts in unions

View 1 answer

Q4. Why the AC will be cut offed what is cut of

Ans.

The AC may be cut off due to various reasons such as power outage, malfunctioning components, or scheduled maintenance.

  • Power outage: AC will be cut off if there is a power outage in the building.

  • Malfunctioning components: If any part of the AC system malfunctions, it may be cut off to prevent further damage.

  • Scheduled maintenance: AC may be cut off temporarily for routine maintenance to ensure optimal performance.

View 1 answer
Discover Shofu Dental interview dos and don'ts from real experiences

Q5. What are the tools used in One AC installed

Ans.

The tools used in One AC installation include screwdrivers, pliers, wire strippers, and a multimeter.

  • Screwdrivers are used to tighten or loosen screws during installation.

  • Pliers are used for gripping and bending wires or components.

  • Wire strippers are used to remove insulation from wires.

  • A multimeter is used to measure voltage, current, and resistance in the AC system.

View 1 answer

Q6. How does AC work what it's principle

Ans.

AC works by transferring heat from inside a building to outside, using a refrigeration cycle.

  • AC units contain a refrigerant that absorbs heat from indoor air and releases it outside.

  • The refrigerant evaporates at low pressure and temperature, absorbing heat in the process.

  • The refrigerant is then compressed, raising its temperature and pressure, before releasing the heat outside.

  • The cycle continues to maintain a comfortable indoor temperature.

  • Examples of AC systems include wind...read more

View 1 answer
Are these interview questions helpful?

Q7. Why we are vaccumming the AC indoor

Ans.

Vaccuuming the AC indoor helps remove dust, dirt, and debris that can accumulate and block airflow, leading to inefficient cooling and potential damage to the system.

  • Vaccuuming helps improve the efficiency of the AC system by ensuring proper airflow.

  • It helps prevent blockages caused by dust and debris, which can lead to overheating and system malfunctions.

  • Regular vaccuuming can prolong the lifespan of the AC unit and reduce the need for costly repairs.

  • It also helps maintain i...read more

View 1 answer

Q8. What kind of gases are in AC

Ans.

The gases in an AC unit typically include refrigerant gases such as R-410A or R-22.

  • Refrigerant gases are used in AC units to absorb and release heat in order to cool the air.

  • Common refrigerant gases used in AC units include R-410A (Puron) and R-22 (Freon).

  • These gases circulate through the AC system in a continuous cycle to facilitate the cooling process.

View 1 answer
Share interview questions and help millions of jobseekers 🌟

Q9. What are the types of AC

Ans.

Types of AC include window AC, split AC, central AC, portable AC, and ductless mini-split AC.

  • Window AC: typically installed in a window and cools a single room

  • Split AC: consists of two units - one indoor and one outdoor - connected by refrigerant lines

  • Central AC: cools the entire house through a system of ducts

  • Portable AC: can be moved from room to room and does not require installation

  • Ductless Mini-Split AC: similar to split AC but does not require ductwork

View 1 answer

Q10. Why the coil is in gas leak

Ans.

Coils are often used in gas leaks to detect the presence of gas due to their sensitivity to changes in electrical resistance.

  • Coils are commonly used in gas leak detectors because they can detect changes in electrical resistance caused by the presence of gas

  • The coil is typically part of a sensor that is designed to trigger an alarm or signal when a gas leak is detected

  • The coil may be connected to a circuit that measures the resistance and triggers an alert if it falls below a ...read more

View 1 answer

Q11. What is time study

Ans.

Time study is a method used to determine the time required to perform a specific task or activity.

  • Time study involves observing and timing each step of a process to calculate the total time needed.

  • It helps in identifying inefficiencies, improving productivity, and setting realistic production goals.

  • Time study can be conducted using various techniques such as direct observation, work sampling, or predetermined motion time systems.

  • For example, in assembly engineering, time stud...read more

Add your answer

Q12. What is your KPI

Ans.

My KPI as an Assembly Engineer is to ensure efficient assembly processes, high-quality output, and meeting production targets.

  • Ensuring efficient assembly processes by optimizing workflow and minimizing downtime

  • Maintaining high-quality output by implementing quality control measures and conducting regular inspections

  • Meeting production targets by monitoring productivity, identifying bottlenecks, and implementing improvements

  • Collaborating with cross-functional teams to resolve a...read more

Add your answer

Q13. Filter types and air

Ans.

Different types of filters are used in air systems to remove contaminants and improve air quality.

  • There are various types of filters such as HEPA filters, activated carbon filters, and electrostatic filters.

  • HEPA filters are highly efficient at removing particles as small as 0.3 microns.

  • Activated carbon filters are effective at removing odors and gases.

  • Electrostatic filters use an electric charge to attract and trap particles.

  • Filters should be regularly replaced or cleaned to ...read more

Add your answer
Contribute & help others!
Write a review
Share interview
Contribute salary
Add office photos

Interview Process at Shofu Dental

based on 3 interviews
Interview experience
3.7
Good
View more
Interview Tips & Stories
Ace your next interview with expert advice and inspiring stories
Share an Interview
Stay ahead in your career. Get AmbitionBox app
qr-code
Helping over 1 Crore job seekers every month in choosing their right fit company
70 Lakh+

Reviews

5 Lakh+

Interviews

4 Crore+

Salaries

1 Cr+

Users/Month

Contribute to help millions

Made with ❤️ in India. Trademarks belong to their respective owners. All rights reserved © 2024 Info Edge (India) Ltd.

Follow us
  • Youtube
  • Instagram
  • LinkedIn
  • Facebook
  • Twitter