I applied via Naukri.com and was interviewed before Jan 2023. There were 2 interview rounds.
The characteristic strength of concrete is influenced by the water-cement ratio.
The water-cement ratio is the ratio of the weight of water to the weight of cement used in the concrete mix.
A lower water-cement ratio generally results in higher characteristic strength.
A higher water-cement ratio can lead to lower characteristic strength and reduced durability.
The water-cement ratio affects the hydration process and the o...
The density of DI, MS, and HDPE pipes varies depending on their composition and manufacturing process.
Density is a measure of mass per unit volume.
DI (Ductile Iron) pipes have a density of approximately 7.2 g/cm³.
MS (Mild Steel) pipes have a density of around 7.85 g/cm³.
HDPE (High-Density Polyethylene) pipes have a density ranging from 0.93 to 0.97 g/cm³.
The density of pipes is an important factor in determining their ...
Workability refers to the ease of handling and placing concrete, while durability refers to its ability to withstand environmental and service conditions.
Workability is influenced by factors such as water content, aggregate size, and admixtures.
Workable concrete can be easily mixed, transported, and placed without segregation or excessive bleeding.
Durability is affected by factors like the water-cement ratio, cement co...
The pressure range of DI and HDPE pipes varies depending on their size and application.
The pressure range of DI (Ductile Iron) pipes typically ranges from 150 psi to 350 psi.
HDPE (High-Density Polyethylene) pipes have a pressure range of 100 psi to 300 psi.
The pressure rating of pipes also depends on their diameter and wall thickness.
For example, a 4-inch DI pipe with a wall thickness of 0.25 inches may have a pressure...
The depth size of 11 kV ABC cable varies depending on the specific installation requirements.
The depth size of 11 kV ABC cable is determined by factors such as soil conditions, local regulations, and installation method.
It is important to consult engineering specifications and guidelines for the specific project to determine the appropriate depth size.
In some cases, the depth size may be specified by the utility compan...
I applied via LinkedIn and was interviewed in Aug 2023. There were 4 interview rounds.
Medhaj Techno Concept interview questions for popular designations
I applied via Walk-in and was interviewed in Feb 2023. There were 3 interview rounds.
What will be the turns ratio if a certain transformer has 400 turns in the primary winding and 2,000 turns in the secondary winding?
Phase angle decreases as frequency increases in a series RC circuit.
As frequency increases, the capacitive reactance decreases, leading to a decrease in phase angle.
At low frequencies, the capacitive reactance is high, causing a larger phase angle.
At high frequencies, the capacitive reactance is low, resulting in a smaller phase angle.
Yes, as the frequency of the voltage applied to a series RC circuit is increased, the phase angle decreases.
Increasing frequency means the reactance of the capacitor decreases, leading to a decrease in the phase angle.
At very high frequencies, the capacitor acts like a short circuit, causing the phase angle to approach zero.
This phenomenon is important in AC circuits and signal processing applications.
Get interview-ready with Top Medhaj Techno Concept Interview Questions
Maintenance of substation is crucial for ensuring uninterrupted power supply.
Regular inspection and testing of equipment
Cleaning and lubrication of moving parts
Replacement of faulty components
Upgrading outdated equipment
Ensuring compliance with safety regulations
Keeping detailed records of maintenance activities
Maintenance of T/L projects involves regular inspections, repairs, and replacements of equipment and components.
Regular inspections should be conducted to identify any potential issues or areas of concern.
Repairs should be made promptly to prevent further damage or safety hazards.
Equipment and components should be replaced as needed to ensure optimal performance and safety.
Proper documentation and record-keeping is imp...
I was interviewed before Feb 2024.
The minimum clearance between the ground and a 220 Kv line is approximately -7 meters.
The negative clearance of -7 meters indicates that the 220 Kv line is below ground level.
This clearance is important to prevent any contact between the line and the ground or any structures.
Proper clearance ensures safety and prevents electrical hazards.
Example: If the ground level is at 0 meters, the 220 Kv line would be 7 meters bel
The spacing between phase conductors of a 220 kV line is approximately 6 meters.
The spacing between phase conductors is crucial for maintaining safety and efficiency in power transmission.
Proper spacing helps prevent electrical arcing and ensures reliable operation of the transmission line.
In the case of a 220 kV line, a spacing of around 6 meters is commonly used to meet safety standards and minimize interference betw
I applied via Company Website and was interviewed in Apr 2023. There were 3 interview rounds.
General SSC level aptitude
I applied via Company Website and was interviewed before Aug 2022. There were 3 interview rounds.
Transmission line parameters are characteristics that define the behavior of electrical signals traveling through a transmission line.
Characteristics include resistance, inductance, capacitance, and conductance
Resistance is the opposition to the flow of current
Inductance is the ability to store energy in a magnetic field
Capacitance is the ability to store energy in an electric field
Conductance is the ability to conduct...
Numerals on line parameters refer to numerical values used to define the characteristics of a line in a system.
Numerals on line parameters are used to specify the impedance, length, capacitance, and other characteristics of a transmission line.
These parameters are crucial for analyzing and designing communication systems, power distribution networks, and other infrastructure.
Examples of line parameters include characte...
Power factor is a measure of how effectively electrical power is being converted into useful work output.
Power factor is a ratio of real power to apparent power in an electrical system.
It is represented by a number between 0 and 1, with 1 being ideal.
A power factor of less than 1 indicates that some of the electrical power is being wasted.
Improving power factor can reduce energy costs and increase efficiency.
Power fact...
NDT stands for Non-Destructive Testing, which is used to assess the quality of a foundation without causing damage.
NDT techniques include ultrasonic testing, radiography, magnetic particle testing, and visual inspection.
Different types of foundations include shallow foundations (such as spread footings and mat foundations) and deep foundations (such as piles and drilled shafts).
NDT can be used to assess the integrity o...
Expected CTC & Job Location are negotiable based on the role and responsibilities.
Expected CTC can vary based on experience, skills, and industry standards.
Job location can be discussed during the interview process to ensure it aligns with the candidate's preferences.
Negotiation on CTC and job location is possible depending on the candidate's qualifications and the company's budget.
It is important to have a clear under...
Top trending discussions
Some of the top questions asked at the Medhaj Techno Concept interview -
The duration of Medhaj Techno Concept interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 51 interviews
Interview experience
based on 760 reviews
Rating in categories
Senior Engineer
188
salaries
| ₹0 L/yr - ₹0 L/yr |
Deputy Manager
149
salaries
| ₹0 L/yr - ₹0 L/yr |
Field Engineer
135
salaries
| ₹0 L/yr - ₹0 L/yr |
Electrical Engineer
131
salaries
| ₹0 L/yr - ₹0 L/yr |
Site Engineer
100
salaries
| ₹0 L/yr - ₹0 L/yr |
TCS
Infosys
Wipro
HCLTech